My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1998
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LINDBERGH
>
6364
>
2300 - Underground Storage Tank Program
>
PR0507806
>
INSTALL_1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2022 11:40:05 AM
Creation date
11/5/2018 5:11:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1998
RECORD_ID
PR0507806
PE
2361
FACILITY_ID
FA0007770
FACILITY_NAME
ATLANTIC AVIATION
STREET_NUMBER
6364
STREET_NAME
LINDBERGH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
02
SITE_LOCATION
6364 LINDBERGH ST 202
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LINDBERGH\6364\PR0507806\INSTALL 1998.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br />PJ• I ¢ � F <br />LOW COST ATG CONSOLE <br />DESCRIPTION <br />INCON's TS -1000/2 system is a complete automatic tank <br />gauge (ATG) and leak detection system for underground <br />storage tanks (UST's). It is designed to provide the tank <br />monitoring and automation features needed in applications <br />ranging from retail gasoline stations to chemical plants, at <br />a cost much lower than comparable systems. The system <br />provides complete inventory information for one or two <br />tanks using state-of-the-art magnetostrictive. sensing tech- <br />nology. The TS -1000/2 is also equipped to monitor liquid <br />probes located in the annular (interstitial) space in double <br />wall tanks or in sumps. Its powerful volumetric leak <br />detection mode performs leak tests which exceed national <br />and local regulations and which can reliably alert you of a <br />leak before it becomes a disaster. <br />VOLUMETRIC LEAK DETECTION <br />The TS -1000 family uses advanced statistical methods to <br />perform fast, reliable, leak tests. These tests not only exceed <br />the EPA requirements fu- ATG's, but also substantially <br />exceed the demanding requirements fortank tightness testers. <br />Leak detection performance claims have been evaluated and <br />certified by an independen{ third party laboratory. The TS - <br />1000 achieves this unmatched level of leak detection perfor- <br />mance as a result of INCON's proprietary "smart" leak test <br />algorithm. You program the unit for a leak rate criterion and <br />probability of detection, and the TS -1000 optimizes its test <br />protocol to meet the actual regulations in your area. Then, <br />while the test is underway, it actually analyzes the condi- <br />tions in your tank to minimize test time and maximize <br />accuracy, regardless of what the conditions may be. Ad- <br />vaned leak detection algorithms and the best technology <br />add up to documented performance that is far ahead of other <br />ATG's. <br />LIQUID SENSING <br />The TS -1000/2 system adds point liquid sensing to the TS - <br />1000's ATG features. The TS -1000/2 can monitor 8 electro - <br />optic or other liquid sensors located between the walls of <br />double wall tanks and pipes, or anywhere else you need to <br />detect liquid. The system allows you to assign a name or <br />alias to each sensor. This name is used when alarms are <br />reported so that the TS -1000 speaks to you in the language <br />of your business and site. <br />COMMUNICATION <br />The TS -100012 includes powerful communication features which <br />make it easy to collect management data and to interface to other <br />systems. Each TS -1000 system includes a full featured RS -232 <br />communications port. It may be used for local communications <br />with other equipment or for remote communications using any <br />Hayes compatible modem. It has full autodialing capability to <br />allow it to send alarm messages to remote monitoring locations. <br />The TS -1000 communication protocol includes security features, <br />error checking, and multi -drop capability. INCON's advanced <br />TS -HOST and TS -LOG IBM PC compatible communications <br />programs complete one of the most powerful communications <br />offerings in the industry. <br />AUTOMATION FEATURES <br />The TS -1000 includes management and automation features that <br />can help your run your business. Reports can be printed automati- <br />cally at programmable times on designated days. The system can <br />detect and record deliveries into each tank. You may program it <br />to automatically reconcile (balance) your inventory over an <br />accounting period. The TS -1000 maybe configured to automati- <br />cally make telephone calls when alarms, deliveries, or other <br />events occur. Leak tests may be scheduled to occur at predeter- <br />mined times. All of these features allow you to customize the <br />operation of the TS -1000 so that it works as a tool to help you run <br />your business and maximize your profits. <br />