My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LINDSAY
>
1533
>
2300 - Underground Storage Tank Program
>
PR0231158
>
COMPLIANCE INFO 2010-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2022 11:57:53 AM
Creation date
11/5/2018 5:15:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2013
RECORD_ID
PR0231158
PE
2361
FACILITY_ID
FA0003749
FACILITY_NAME
SJ REGIONAL TRANSIT
STREET_NUMBER
1533
Direction
E
STREET_NAME
LINDSAY
STREET_TYPE
ST
City
STOCKTON
Zip
952054498
APN
15302004
CURRENT_STATUS
02
SITE_LOCATION
1533 E LINDSAY ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LINDSAY\1533\PR0231158\COMPLIANCE INFO 2010-2013.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3,Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General information <br /> Facility Name: RJ RTD Bldg.No.: <br /> Site Address: 1535 E LINDSAY ST City: STOCKTON Zip: 95205 <br /> Facility Contact <br /> Person: Contact Phone No.: ( ) <br /> Make/Model of Monitoring System: INCON Date of Testing/Servicing: 05-15-13 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ectad/serviced: <br /> Tank ID: TRANS Tank ID: DIESEL 4 <br /> ® In-Tank Gauging Probe. Model: MAG ® In-Tank Gauging Probe, Model: MAG <br /> ® Annular Space or Vault Sensor. Model: HI LOW ® Annular Space or Vault Sensor. Model: HI LOW <br /> ® Piping Sump/Trench Sensar(s). Model: ULS ® Piping Sump/Trench Sensor(s). Model: ULS <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ® Tank Overfill/High-Level Sensor. Model: FLAPPER ® Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: WASTE OIL TanklD: NEW OIL <br /> ® In-Tank Gauging Probe. Model: MAG ® In-Tank Gauging Probe. Model: MAG <br /> ® Annular Space or Vault Sensor. Model: ELS ® Annular Space or Vault Sensor. Model: ELS <br /> EI Piping Sump/Trench Sensor(s). Model: ULS ® Piping Sump/Trench Sensor(s). Model: ULS <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> ® Dispenser Containment Sensor(s). Model: ULS ® Dispenser Containment Sensor(s). Model: ULS <br /> ® Shear Valve(s). ® Shear Velvets). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Floats)and Chain(s). <br /> Dispenser ID: 5.6 Dispenser ID: <br /> ® Dispenser Containment Sensor(s). Model: ULS ❑ Dispenser Containment Sensor(s). Model: <br /> ® Shear Velvets). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Floats)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Floats)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> -If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verity that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ❑System set-up ❑Alarm history report <br /> Technician Name(print): FELIX RAMIREZ Signature: <br /> Certification No.: 5273934-UT License No: 08-1740 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2° STREET GALT,CA 95532 Date of Testing/Servicing: 05-15-13 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.