My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOCKE
>
12355
>
2300 - Underground Storage Tank Program
>
PR0504062
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2022 9:13:06 AM
Creation date
11/5/2018 5:28:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0504062
PE
2332
FACILITY_ID
FA0006065
FACILITY_NAME
PAHL, JOHN A
STREET_NUMBER
12355
Direction
E
STREET_NAME
LOCKE
STREET_TYPE
RD
City
LOCKEFORD
Zip
95237
APN
05129031
CURRENT_STATUS
04
SITE_LOCATION
12355 E LOCKE RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOCKE\12355\PR0504062\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
2/9/2018 11:25:33 PM
QuestysRecordID
3789027
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Y.ZJ aC[9 <br /> STATE OF CALIFORNIA COs, <br /> STATE WATER RESOURCES CONTROL BOARD ..,a <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> ta> <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION 7 PERMANENTLY CLOS ON SITE <br /> ONE ITEM F--] 2 INTERIM PERMIT F74 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED ' <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: / 1/777 0° <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I,D.# //, B. MANUFACTURED BV: it <br /> C. DATE INSTALLED(MO/DAY/YEAR) . 'C D. TANK CAPACITY IN GALLONS: (�Q <br /> II.TANK NTENTS IFA-11S MARKED,COMPLETE ITEM C. <br /> 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C. ❑ 1aUN EADED ❑ 3 DIESEL ❑ 6 AVIATIONGAS <br /> A. ❑ 2 PETROLEUM ❑ LAR <br /> 80 EMPTY �1 PRODUCT RE AIDUM <br /> E ❑ 4 GASAHOL ❑ 7 METHANOL <br /> [[[""' UNLEADED ❑ 5 JET FUEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B,AND C,ANDALL THAT APPLIES IN BOX DAND <br /> A. TYPE OF F-11 DOUBLE WALL F-13 SINGLE WALL WITH EXTERIOR LINER 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) ❑ 99 OTHER <br /> B. TANK F-] 1 BARE STEEL F-12 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD WI FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ e POLYVINYL CHLORIDEUMINUM ❑ B 100% METHANOL COMPATIBLE WIFRP <br /> (PrimaryTank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑�/3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR F—] 5 GLASS LINING ❑ 6 UNLINED <br /> LINING J95 UNKNOWN ❑ 99 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? VES_ NO_ <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION F-15 CATHODIC PROTECTION ❑ 91 NONE 95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A 9 NKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 �STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> - <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION 'U UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ 9 INTERSTITIAL <br /> ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUT TIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> ❑ 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE 'Fe5 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAYNR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO F-1SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME DATE <br /> (PRINTED A SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> STATE I.D.# = I el �> <br /> PERMITNUMBER P RMIT APPROVED BWDATE PERMIT EXPIRATION DATE c p <br /> (_ O �Y I <br /> FORM B (7-91) THIS FORM MUST BE ACCOMPANIEDBY A PERMIT APPLICATION•FORM A,UNLESS A CURRENT D. <br /> FORMA HAS BEEN FILE <br /> 0 0 117 0348 <br />
The URL can be used to link to this page
Your browser does not support the video tag.