• Associated Environmental Systems, Inc. <br /> p. 0. Box 80427 <br /> Bakersfield, CA80 <br /> (805) -393-2212 <br /> Invoice Number <br /> HYDROSTATIC PRODUCT LINE TEST WORK SHEET <br /> I TEST I PRODUCT I START I END I START I END I TEST VOL. <br /> I NO. I I TIME I TIME I VOL. (ML) i VOL. (ML) i DIFF. (ML) <br /> I I �/2-v/� , G) ::30 1-MOs I <br /> I <br /> 2/S _1 -2-03 <br /> � i l 2 <br /> I Z 203 1 <br /> i 1 <br /> 13Zc�I _/S�__i _ /73 <br /> II I /3 Zo I /3.3s i _�23 1 /,60 1 /3 , <br /> I I — <br /> 2 I <br /> I <br /> I <br /> I I I 1 <br /> I I I I I I I <br /> i <br /> I I i -� <br /> Divide the volume differential by the test time ( 15 minutes) and <br /> multiply by 0. 0158311, which will convert the volume differential <br /> from milliliters per minute to gallons per hour. <br /> The conversion constant is found by : <br /> (60 min/hr) / (3790 ml/gal) = 0. 0158311 (min/hr) (gal/ml ) <br /> The conversion constant causes the milliliters and minutes to <br /> cancel out. <br /> Ex. If the level dropped 3m1 in 15 minutes then: <br /> 3/15 ml . /min. X 0. 0158311 (min/hr) (981/my = 0. 003 gal/hr. <br /> RESULTS OF THIS WORK SHEET TO BE COMPILED ON RESULTS SHEET. <br />