Laserfiche WebLink
IFIED PROGRAM CONSOLIDATED FOR I ,Z 07TANK: TA0160005 <br /> PR#: PRO231600 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE IFAC q FAC", FA000NS7 <br /> '� U l (two pages per tank) <br /> Page 4 of 7 <br /> TYPE OF ACTION ❑ INEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check orth•item only) <br /> ❑ 7 PERMANENTLY CLOSED ON SITE <br /> F] 3 RENEWAL PERMIT <br /> (Speciryrcaran-forlocalweonly) (spociiyreason-forlocaluseonly) [j 8 TANK REMOVED 'fait <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As FACILITY ID: PR it <br /> LATHROP GAS&FOOD MART* T <br /> FA0000957 PR0231600 <br /> LOCATION WITHIN SITE(optional) 14800 S HWY 99,MANTECA 431 <br /> PHONE <br /> 1.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 5 439 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes []No 434 <br /> TA0160005 OWENS CORNING lf"Yes",wmpktcompageforcwbwmp ml, <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 43f, NUMBER OF COMPARTMENTS 417 <br /> 111/1989 12:00:OOAM 10,000 <br /> ADDITIONAL DESCRIPTION(For localinc only) 434 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® i.MOTOR VEHICLE FUEL ❑ la.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.!ET FUEL <br /> (Ifnsarkedwmp)ete Petroleum Type) ❑ Ib PREMIUM UNLEADED ® 3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ I c.MIDGRADE UNLEADED ❑ 4.GASOHOL ❑ 99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT <br /> COMMON NAME(from Haaurdous Materials invent.,pagcl 441 CAS#(from Hazardous Ma[crials Inrxntoey page) 442 <br /> ❑ 4.HAZARDOUS WASTE <br /> (lmludes Used oil) <br /> ❑ 95.UNKNOWN <br /> [H.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ I.SINGLE WALL ❑ 3 SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑95.UNKNOWN <br /> ® 2.DOUBLE WALL ❑4 SINGLE WALL IN VAULT ❑99.OTHER <br /> TANK MATERIAL-primary tank ❑ 1_BARE STEEL [!] FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 444 <br /> (Check ooc It=only) ❑ 2 STAINLESS STEEL ❑ STEEL CLAD WIFIBERGLASS ❑ 8 FRP COMPTIBLE Wf I00%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99.OTHER <br /> TANK MATERIAL-secondary tank ❑ I BARE STEEL Q 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (Check one itrnn only) ❑ 2.STAINLESS STEEL ❑ 4.STEEL CLAD WtRBERGLASS ❑ S.FRP COMPTIBLE WA 00%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑99.OTHER <br /> ❑ 5_CONCRETE <br /> TANK INTERIOR LINING ❑ 1.RUBBER LINED ❑ 3.EPDXY LINING ❑ 5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 441 <br /> OR COATING <br /> (Clunk,.a item only) ❑ 2 ALKYD LINING ❑ 4 PHENOLIC LINING ❑ 6 UNLINED ❑ 94.OTHER <br /> (Far local use only) <br /> OTHER CORROSION ❑ I MANUFACTURING CATHODIC ❑ 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 449 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> ❑ 4 IMPRESSED CURRENT E]99 OTHER <br /> (Check one item only) <br /> ❑2 SACRIFICIAL ANODE {Forlocal use only) <br /> SPILL AND OVERFILL YEAR INSTALLE45a TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) ® l SPILL CONTAINMENT 2,003.00 OPW ❑ I ALARM 2,003.00 ❑ 3 FILL TUBE SHUT OFF VAL,2,003.00 <br /> ® 2 DROPTUBE 2,003.00 OPW ❑ 2 BALL ❑ 4 EXEMPT <br /> ® 3 STRIKER PLATE 2,003.00 W/MAGNET FLOAT <br /> W.TANK LEAK DETECTION(A deseriptionof the monitoring program shall be submiaad to the local agency.) <br /> IF SINGLE WALL TANK(Check as that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ I VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) {Check we nen'only) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) []6 VADOSE ZONE ❑ 1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ® 2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑ STANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION I PERMANENT CLOSURE[N PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAIN]NG 436 TANK FILLED WITH INERT MATERIAL? 457 <br /> ❑Yes ❑ No <br /> UPCF(12199 revised) <br />