Laserfiche WebLink
SYOEM SET—UP REPORTWage1) <br /> SYSTEM SETUP _iA-II'1UNICATIONS SETUP AUTO DIAL TIME SETUP: <br /> - - - - - - - -- - - - - - - - - <br /> FEB 29. 2008 8:26 AM <br /> D 5:FQ FMS <br /> PORT SE17INGS: DIAL ON DATE <br /> MAR 1, 2007 <br /> SYSTEM UNITS COMM BOARD : I (ED1M ) DIAL TIME DISABLED <br /> U.S. RS-232 SECURITY RECEIVER REPORTS: <br /> SYSTEM LANGUAGE CODE : DISABLED <br /> ENGLISH COMM BOARD 2 (EDIM ) RS-232 END OF MESSAGE <br /> SYSTEM DATE/TIME FORMAT R3_232 SECURITY DISABLED <br /> MON DD YYYY' HH:MM:SS xM CODE DISABLED <br /> 235419 7-11 32190 AUTO D- - ALARM SETUP <br /> 4943 S. STATE RT. 99 COMM BOARD 3 (S-SAT ) <br /> STOCKTON.CA.95215 BAUD RATE 9600 D 5:FQ FMS <br /> A0369068905001 PARITY NONE <br /> STOP BIT 1 STOP IN-TANK ALARMS <br /> SHIFT TIME 1 : 7:00 AM DATA LENGTH: 8 DATA IALL:LEAK ALARM <br /> SHIFT TIME 2 DISABLED RS <br /> -232 SECURITY -ALL:HIGH WATER ALARM <br /> SHIFT TIME 3 : DISABLED ALL:OVERFILL ALARM <br /> SHIFT TIME 4 DISABLED DTR NORMAL STATE: HIGH ALL:LOW PRODUCT ALARM <br /> COMM BOARD 5 (RS-485) ALL:SUDDEN LOSS ALARM <br /> SHIFT SIR PRINTOUTS ALL:HIGH PRODUCT ALARM <br /> DISABLED BAUD RATE 2400 ALL:INVALID FUEL LEVEL <br /> DAILY BIR PRINTOUTS PARISTOPTY EVEN BIT I STOP ALL :HIGHEWATER WARNING <br /> ENABLED <br /> TICKETED DELIVERY DATA LENGTH: 7 DATA ALL:DELIVERY NEEDED <br /> DISABLED RS-232 SECURITY ALL:MAX PRODUCT ALARM <br /> TANK PER TST NEEDED WRN CODE . DISABLED ALL:GROSS TEST FAIL <br /> DISABLED ALL:PERIODIC TEST FAIL <br /> TANK ANN TST NEEDED WRN COMM BOARD 6 (RS-232) ALL:ANNUAL TEST FAIL <br /> DISABLED BAUD RATE 1200 ALL:PER TST NEEDED WRN <br /> PARITY : ODD ALL:ANN TST NEEDED WRN <br /> LINE RE-ENABLE METHOD STOP BIT I STOP HLL:PER TST NEEDED ALM <br /> PASS LINE TEST DATA LENGTH: 7 DATA ALL:ANN TST NEEDED ALM <br /> RS-232 SECURITY ALL:NO CSLD IDLE TIME <br /> LINE PER TST NEEDED WRN CODE : DISABLED ALL:CSLD INCR RATE WARN <br /> DISABLED ALL:A000_CHART CAL WARN <br /> LINE ANN TST NEEDED WRN ALL:RECON WARNING <br /> DISABLED AUTO TRANSMIT SETTINGS: ALL:RECON ALARM <br /> ALL:LOW TEMP WARNING <br /> PRINT TC VOLUMES AUTO LEAK ALARM LIMIT ALL:MISSING TICKET WARN <br /> ENABLED DISABLED ALL:GROSS FAIL LINE TNK <br /> AUTO HIGH WATER LIMIT <br /> TEMP COMPENSATION DISABLED LIQUID SENSOR ALMS <br /> VALUE (DEG F ) : 60.0 AUTO OVERFILL LIMIT ALL:FUEL ALARM <br /> STICK HEIGHT OFFSET DISABLED ! ALL:SENSOR OUT ALARM <br /> DISABLED AUTO LOW PRODUCT <br /> ULLAGE: 90°< DISABLED ALL:SHORT ALARM <br /> AUTO THEFT LIMIT ALL:WATER ALARM <br /> H-PROTOCOL DATA FORMAT DISABLED ALL:WATER OUT ALARM <br /> HEIGHT AUTO DELIVERY START ALL:HIGH LIQUID ALARM <br /> PRECISION TEST DURATION DISABLED ALL:LOW LIQUID ALARM <br /> HOURS: 504 AUTO DELIVERY END ALL:LIQUID WARNING <br /> DAYLIGHT SAVING TIME DISABLED <br /> ENABLED AUTO EXTERNAL INPUT ON COMM SIDE DIM ALM <br /> START DATE DISABLED ALL:DISABLED DIM ALARM <br /> MAR WEEK 3 SUN AUTO EXTERNAL INPUT OFF ALL:COMMUNICATION ALARM <br /> START TIME DISABLED <br /> 2:00 AM AUTO SENSOR FUEL ALARM RECONCILIATION ALM <br /> END DATE DISABLED ALL:PROD THRESHOLD ALM <br /> NOV WEEK 2 SUN AUTO SENSOR WATER ALARI°l ALL:CLOSE SHIFT WARNING <br /> END TIME DISABLED ALL:CLOSE DAILY WARNING <br /> 2:00 AM AUTO SENSOR OUT ALARM <br /> RE-DIRECT LOCAL PRINTOUT DISABLED _ <br /> DISABLED --_ - <br /> RECEIVER SETUP: <br /> EURO PROTOCOL PREFIX <br /> S <br /> D 5:FG FMS <br /> C10.90.3.94 3001 <br /> PCVR TYPE: COMPUTER <br /> PORT NO: 3 <br /> RETRY NO: 5 <br /> RETRY DELAY: 5 <br /> CONFIRMATION REPORT: OFF <br /> 0 2006 Walton Engineering,Inc. <br />