My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
COMPLIANCE INFO_2008-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/5/2018 8:17:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2009
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4943\PR0506488\COMPLIANCE INFO 2008-2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
300
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Exhibit 4 <br /> Determination of Static Pressure Performance of the <br /> Healy Clean Air Separator <br /> (Executive Orders VR-201-D and VR-202-D) <br /> 1 APPLICABILITY <br /> Definitions common to all certification and test procedures are in: <br /> D-200 Definitions for Vapor Recovery Procedures <br /> For the purpose of this procedure, the term "ARB" refers to the California Air <br /> Resources Board, and the term "ARB Executive Officer' refers to the Executive <br /> Officer of the ARB or his or her authorized representative or designate. <br /> 1.1 This test procedure is used to quantify the vapor tightness of the Healy Clean Air <br /> Separator (CAS) pressure management system installed as part of a gasoline <br /> dispensing facility (GDF) under either Executive Order VR-201-D or VR-202-D. <br /> 2 PRINCIPLE AND SUMMARY OF TEST PROCEDURE <br /> 2.1 The Clean Air Separator, while isolated from the vapor recovery system, is <br /> evaluated for vapor integrity using a vacuum decay procedure. The vacuum <br /> decay after 5 minutes is compared with an allowable value. The allowable value <br /> is based upon the initial vacuum level when conducting the test using the table <br /> provided in this test procedure. <br /> 2.2 A positive pressure decay procedure is included that conducts the same <br /> evaluation as the vacuum decay but with positive pressure. This test is <br /> conducted if there is insufficient vacuum (not greater than—2.00" wc) to conduct <br /> the vacuum decay. Districts have the authority to specify in the permit conditions <br /> that this positive pressure test is to be conducted even if the vacuum test has <br /> been conducted. <br /> 3 RANGE <br /> 3.1 The full-scale range of the electronic measuring device shall not exceed <br /> 0-20.00" we with a minimum accuracy of not less than 0.25 percent of full-scale. <br /> 4 INTERFERENCES <br /> 4.1 Leaks in the piping for the Clean Air Separator could bias the test results toward <br /> non-compliance. <br /> Healy Clean Air Separator Test Procedure, Exhibit 4—Executive Orders VR-201-D and VR-202-D <br />
The URL can be used to link to this page
Your browser does not support the video tag.