Laserfiche WebLink
MONITCCING SYSTEM CERTIF 'ATION <br /> MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS-350 <br /> CERTIFICATION / TEST DATE: July 27, 2009 <br /> Al. FACILITY A2. OWNER <br /> Name 7-Eleven Market#2368/Store#32190 Name 7-Eleven, Inc <br /> Address 4943 South State Route 99,Stockton, CA 95206 Address P.O. Box 711, Dallas,TX 75221 <br /> Phone# 209-939-0679 Phone 805-523-2949 <br /> Contact Jay Stemley contact Shane Partridge <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 600 E. Main Street,Stockton,CA 95202 Address P.O.Box 1025,W.Sacramento,CA 95691 <br /> Notified July 21,2009 Lie# 617238 A,B,Haz <br /> Inspector Muniappa Naidu Contact Richard Walton <br /> Phone# 209-468-3439 Phone# 916-825-3203 <br /> B. INVENTORY OF EQUIPM ENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br /> 131: TANKS <br /> Tank#1 (Product): Gasoline-87 Tank#2 (Product): Gasoline-89 <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> El Annular Space or Vault Sensor Model: El Annular Space or Vault Sensor Model: <br /> ❑ Piping Sump/Trench Sensor(s) Model: ❑ Piping Sump/Trench Sensoria) Model: <br /> ❑ Fill Sump Sensoria) Model: ❑ Fill Sump Sensor(s) Model: <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ■ Electronic Line Leak Detector Model: 0848480.001 <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> Tank#3 (Product): Gasoline-91 Tank#4 (Product): _ <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ❑ Annular Space or Vault Sensor Model: ❑ Annular Space or Vault Sensor Model: <br /> ❑ Piping Sump/Trench Sensor(s) Model: ❑ Piping Sump/Trench Sensor(s) Model: <br /> ❑ FIII Sump Sensors) Model: ❑ Fill Sump Sensors) Model: <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> B2: DISPENSERS/UDC's <br /> Dispenser#: Dispenser# <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Floats)and Chain(s) _ <br /> Dispenser#: Dispenser#: <br /> ❑ Dispenser Containment Sensoria) Model: ❑ Dispenser Containment Sensoria) Model: <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chains) ❑ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: Dispenser A: <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensoria) Model: <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the <br /> layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply): <br /> ■ System set-up ■ Alarm History Report <br /> W Af WALTON <br /> Signature: aX — ENG <br /> INEERING,INC. <br /> Technician/CertM JessieWadkins/6353915307886-UT Date: .July 27, 2009 <br /> ©2006 alton Engineenng,Inc. <br />