My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
COMPLIANCE INFO_2004-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/5/2018 8:19:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2007
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4943\PR0506488\COMPLIANCE INFO 2004-2007.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
226
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JAR126-2005 03:39P FROM:PRRX SERUICES 520 88B 3923 9120946834330011 P:2 <br /> Reviewed by David Rabb Prexair Service,Inc.QA <br /> Approved by Randy Golding Tracer Ttghr® <br /> Update 10.14-04 <br /> Version V4 <br /> Work Plan <br /> Site Owner <br /> Site Name `]-Eleven cSiarQ # 32190 <br /> Address ' 13 S'• Sta#Q Rn,,+L99 <br /> City and State Siae.ktot O—A <br /> In Service Enhanced Leak Detection Protocol OS-ELD) <br /> Introduction (The IS-ELD Method Utilizes an Onsite Site Laboratory for Real-Time Results) <br /> In Service Enhanced Leak Detection (IS-ELD) means a test method that ascertains the physical integrity of an <br /> underground tank system by introduction, and external detection, of a substance that is not a component of the fuel <br /> formulation that is stored in the tank system while the system is in service. The test method is third party certified for the <br /> capability of detecting both vapor and liquid phase releases from the underground storage tank system. The Enhanced <br /> Leak Detection test method is capable of detecting a leak rate of at least 0.005 gph or less, with a probability of detection <br /> of at least 95%and a probability of false alarm no greater than 5%." <br /> Concept <br /> Tracer Tight®is a unique method of testing underground storage systems for tightness. A unique chemical called a tracer <br /> is added to the product stored in the tank. The tracer is an inert chemical that evaporates readily from the fuel. After <br /> tracer is added to the system,it is distributed between the vapor and liquid inside the tank. Use of the system carries the <br /> tracer throughout the piping. If any small leak exists in the system,the tracer is allowed to escape from the system,either <br /> as a vapor or as a dissolved component of the liquid. Once outside the system,the dissolved tracer evaporates from the <br /> liquid and the tracer vapors begin to migrate away from the location of the leak in all directions. After an appropriate <br /> waiting period, the tracer vapors are detectable at least ten feet or more away from the leak in all directions. Samples of <br /> air collected from the soil within the radius of detection of the tracer reveal the leak as a presence of the tracer chemical. <br /> Because the tracer chemical is not normally found in the environment or in fuel products, the Tracer Tighte method is <br /> able to discriminate between previous contamination and current leakage. <br /> Contractor <br /> It is important that before Praxair arrives on site that the tanks are full and that you discontinue future fuel drops <br /> till the test is completed. It is not desirable for the station to run out of fuel If a fuel drop becomes necessary in <br /> order to keep the station open then contact Praxair's site Proiect manager and schedule the drop while the crew is <br /> onsite. A clean fuel drop reduces the possibility of having to retest the site <br /> A contractor capable of repairing any exposed component in the system including having spare parts must be <br /> onsite to expedite repairs The contractor skills must include the ability to operate and make adjustments to the <br /> setting of the electronics controlling the fueling system Because of the nature of tracer testing the contractor <br /> must be capable and committed to working longer hours and extended days outside of normal work week The <br /> owners contractor will be in complete control of the fueling system and it is the contractors responsibility to <br /> operate the fueling system properly and to reassemble the system back into a pretest configuration Praxair <br /> Service.Inc.is only resuonsible for testin the fueling system and is not responsible for it's operation <br /> THIS INFORMATION IS THEPROPERTYOFPRAXAIR SERVICE,INC <br /> 1 of <br />