My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
INSTALL_2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:30 PM
Creation date
11/5/2018 8:20:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2003
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4943\PR0506488\2003 INSTALL .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
181
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UL/ULC Listed RED THREAD° IIA Piping <br /> GENERAL SPECIFICATIONS <br /> Primary Piping Secondary Containment Piping <br /> SCOPE SCOPE <br /> PIPE- Pipe shall be manufactured by Smith Fibercast by PIPE- Pipe shall be manufactured by Smith Fibercast by <br /> a filament winding process using a thermosetting epoxy a filament winding process using a thermosetting epoxy <br /> resin to impregnate strands of continuous glass filaments resin to impregnate strands of continuous glass filaments <br /> which are wound around a mandrel at a prescribed helix which are wound around a mandrel at a prescribed helix <br /> angle and tinder controlled tension. All pipe will be angle and under controlled tension. <br /> supplied with matching tapered T.A.B." (Threaded and <br /> Bonded) coupling and spigot ends or T.A.B. spigot x CONSTRUCTION <br /> spigot ends. 3"-4"PIPE- RED THREAD IIA pipe shall have continuous <br /> glass fibers filament wound at a 35% helix angle in a <br /> CONSTRUCTION matrix of epoxy resin. Pipe shall be in compliance with <br /> 2"-4"PIPE- RED THREAD IIA pipe shall have continuous ASTM D2310 and classified by its designation code. Pipe <br /> glass fibers filament wound at a 35W helix angle in a shall meet all performance requirements and mechanical <br /> matrix of epox'v resin. Pipe shall be in compliance with I properties.and shall be classified with the following <br /> ASTM D2310 and classified by its designation code. Pipe designation codes: <br /> shall meet all dimensional and perfon»ailcp Size Designation Code at 73.4' F <br /> requirements. mechanical properties. and shall be i 3- RTRP-11 AE <br /> classified with the following designation codes: 4- RTRP-11 AF <br /> Size Designation Code at 73.4'F <br /> 2".3" RTRP-11AE ITEMS <br /> 4" RTRP-11AF 3"-4"PIPE-Glass fiber reinforced filament wound pipe <br /> with Plain end by Plain and. Pipe to be factory <br /> ITEMS prooftested at the following pressures: <br /> 2"-4"PIPE -Glass fiber reinforced filament wound pipe 3'-300 psig(minimum) <br /> with matching tapered T.A.B. (Threaded and Bonded) 4--265 psig(minimum) <br /> coupling and spigot ends. Pipe to be factory prooftested <br /> at the following pressures: 3"-4"FITTINGS - Compression molded two-piece fittings <br /> 2--375 psig shall be manufactured using a vinyl ester molding <br /> 3'-300 psig compound. The molding compound shall be reinforced <br /> with a minimum of 60e08 chopped glass fiber. <br /> 4--265 psig <br /> 2"-4"FITTINGS-Compression molded fittings shall be ADHESIVES- .adhesive and curing agents shall be either <br /> manufactured using an epoxy molding compound. The UL Listed DS-8000 or DS-7000 series adhesive. Consult <br /> molding compound shall be reinforced with a minimum I Smith Fibercast's installation manual No. 82160 for <br /> of 45%chopped glass fiber. In-line fittings are filarnent recommended heat curing techniques. <br /> wound. I JOINING TECHNIQUES <br /> ADHESIVES-Adhesive and curing agents shall be either 3"-4"PIPE and FITTINGS- Pipe shall be joined with <br /> UL Listed DS-8000 or DS-7000 series adhesive. either DS-8000 or DS-7000 series adhesive. Fittings shall <br /> Consult Smith Fibercast's installation manual No. 82160 be joined with either DS-7000 or DS-8000 series <br /> for recommended heat curing techniques. adhesives and filler. Material to be installed in <br /> accordance with Smith Fibercast's installation manual <br /> JOINING TECHNIQUES No. B2160. <br /> 2"-4"PIPE and FITTINGS-Pipe and fittings shall be TESTING <br /> joined with DS-8000 or DS-7000 series adhesive using <br /> matching tapered bell/coupling and spigot. Material to 3"-4"SECONDARY CONTAINMENT PIPE SYSTEMS- <br /> be installed in accordance with Smith Fibercast's Secondary containment pipe systems should be tested <br /> installation manual No. B2160. prior to use to assure soundness of all joints and <br /> connections. Consult Smith Fibercast's installation <br /> TESTING manual No. B2I60. <br /> 2"-4"PRIMARY PIPE SYSTEMS -Primary pipe systems <br /> should be tested prior to use to assure soundness of all <br /> joints and connections. Consult Smith Fibercast's <br /> installation manual No. 82160. <br /> 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.