My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
INSTALL_2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:30 PM
Creation date
11/5/2018 8:20:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2003
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4943\PR0506488\2003 INSTALL .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
181
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
♦ Flexible <br /> Positive Seal Quality Materials <br /> Sump Entry Corrosion Resistance <br /> Flexible entry boots have been The exterior studded metal I <br /> tested to withstand a minimum compression ring that provides <br /> of 6' of liquid head pressure. the positive sealing pressure is <br /> These seals provide a studded encapsulated within rubber to <br /> flange connection to create a protect it from corrosion. More - - <br /> positive and secure seal where <br /> than a 1/8"of rubber isolatesthe " <br /> the rubber contacts the sump metallic studded ring from the <br /> wall and also around the pipe or ground environment. All studs <br /> conduit. Tightening down on a are made of 401 stainless steel <br /> series of stud fasteners with a and are only exposed on the <br /> compression ring provides a inside of the containment sump. <br /> high compression mechanical <br /> seal compared to screw on type Chemical Compatibility <br /> bulkhead seals. All seals are made of specially <br /> formulated Buna-N rubber <br /> Angled Entries compound which has been <br /> Pipe and conduit entering independently tested to insure its ' <br /> the containment sumps may compatibility with a wide <br /> not be perpendicular with assortment of chemicals. These <br /> the sump wall. Angled entries tests include measuring the <br /> material's retention of properties <br /> are generally a result of <br /> as well as the physical <br /> directional plumbing restrictions <br /> characteristics of the seal after <br /> on the inside of the <br /> containment chamber due to exposure. <br /> space limitations. Flexible entry UL/ Listed <br /> boots are flexible enough to <br /> permit angled pipe or conduit Environ flexible entry boots are Listed with Underwriters <br /> entries (on two axises) into the Laboratories, Inc., (UL). The scope of the tests include broad <br /> sidewall of a containment compatibility testing for both petroleum products and burial <br /> chamber. All flexible entry environments as well as physical testing to confirm the entry boots <br /> boots permit angled entries up structural integrity and liquid tightness. <br /> to a 15 degree angle off the Sizes Available <br /> perpendicular center line in any <br /> direction without leaking or i <br /> putting undue stress on the pipe <br /> or conduit seal. .84" 4" FEB-3050 Designed to seal 112"rigid conduit _{ <br /> 1.05" 4" FEB-3075 Designed to seal 31C rigid conduit <br /> Universal Alignment 1.05' 3.25" FEB-3075-A Designed to seal 3/4"rigid conduit. <br /> These seals are also capable of = = 1 32" 4.25" FEB-3100 Designed to seal t"rigid conduit <br /> • R" <br /> universal pipe alignment either ,x <br /> up and down or side to side. This ® 1.81" 4.25" FEB-3150 Designed to seal 1-1/1"standard rigid pipe. <br /> feature allows accommodation of (0 0 1.81" 4,75" FEB-5150 Designed to seal 1-1/1"Gaulerflexible pipe. <br /> pipe entry holes which are <br /> 1.81" 6.25" FEB-6150 Designed roseal t-1Y1"GeoRexfle>ahle pipe. <br /> installed slightly off exact center <br /> alignment in the chamber wall. <br /> --� 2.37" 6.25" FEB-6100 Designed to seal 2"GeaRexflexible pipe. <br /> This movement will prevent the <br /> chamber wall from putting 3.50" 6.25" FEB-6300 Designed to seal 3"standard rigid pipe. <br /> 0 <br /> undue stress on the pipe 3.50" 6.25" *FEB-6350 Designed roseal 3"rigid ducting. <br /> coupling/fitting joint and the 3.90" 7.75" FEB-7390 Designed to seal 3-112"custom pipe. <br /> entry boot as well. For flexible .� <br /> piping applications within 4.50" 7.75" FEB-7400 Designed to seal 4"standard rigid pipe. <br /> dispenser sumps, the stresses 4.50" 7.75' *FEB-7450 Designed to seal 4"GeoDuctflexible ducting. <br /> on the pipe fittings below the <br /> fi.50" 9" FEB-8600 Designedroseal 6"standard rigid pipe. <br /> product inlets are minimized by <br /> the boot's flexibility. 'These b=regui ea Spit Hmucer Donut sdd sepaatep,bunnclude an aimem m alawlorappmpnam unnng. <br /> Patent claims allowed. environ <br /> fin` iron <br /> e•,n rm.evropep 620 Pennsylvania Drive•Exton,PA 19341 •Tel:(610)321-0200•Customer Service(800)833-1883 C v v' i <br /> j.,"neaarsmac a Fax:(610)321-0406•http://www.envproduct.com•U.S.Patent 5263794,5271518,5297896.5366318, " 1 e " . . , , " <br /> 5346625.5398976,Other U.S.and Worldwide Patents Pending•®Copyright 1997 <br />