Laserfiche WebLink
C� <br />San Joaquin County Y�� <br />Environmental Health Department Y <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.or /� eh <br />Underground Storage Tank Program Inspection Report <br />Facility Name: Facility Address: Date: <br />7 -ELEVEN INC #32190 4943 S HWY 99 Stockton ADrll 1 <br />320 I HSC 25290.1(c3), I Secondary containment not constructed to prevent water intrusion <br />Page 2 of 6 <br />201 <br />■V ■R ❑COS <br />❑V ❑R ACOS <br />D ❑R ii COS <br />❑V ii aCOS <br />❑V c Li COS <br />ii c ❑COS <br />❑V ii ❑COS <br />❑V ii ❑COS <br />■V w ❑COS <br />aV c Li COS <br />oV ❑R ❑COS <br />❑V ❑R Li COS <br />L)V <br />❑R <br />On Site Records <br />201 <br />CCR 2712(b) <br />Failed to maintain alarm logs and/or records of follow up actions <br />202 <br />1 CCR 2712(b) <br />Failed to maintain cathodic protection test records on site for at least 6 112 years <br />203 <br />CCR 2712(b) <br />Failed to maintain records of monitoring, repair, lining, and upgrades on site <br />204 <br />CCR 2712(i) <br />Current monitoring plan approved by the EHD not found on site <br />205 <br />CCR 2712(i) <br />Operating permit not on site <br />206 <br />HSC 25294, 25295 <br />Failed to record or report unauthorized release in appropriate time frame <br />207 <br />CCR 2715 <br />Designated operator did not inspect all required items and/or the inspection reports not completed <br />208 <br />CCR 2715 <br />Designated operator monthly inspection reports not maintained on site for at least 12 months <br />209 <br />CCR 2715(!) <br />Designated operator employee training not performed or log not kept <br />210 <br />CCR 2715(f)(2) <br />Unstaffed facility failed to have or implement a training program approved by the EHD <br />211 <br />HSC 25281.5(b)(2) <br />Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br />212 <br />HSC 25281.5(b)(3) <br />Unburied emergency generator fuel piping not visually inspected at least monthly or log kept <br />USS' System Observations <br />301 <br />HSC 25292.1 <br />UST system is not operated to prevent unauthorized release, including spills and overfills <br />302 <br />HSC 25291(b) <br />UST system incapable of detecting leak from primary into secondary containment (pre -Jul 2003) <br />303 <br />HSC 25290.2(d) <br />Monitoring system not maintained to detect entry into secondary containment (Jul 2003 -Jun 2004) <br />304 <br />HSC 25290.1(d) <br />Monitoring system not maintained to detect entry into secondary containment (after Jul 2004) <br />305 <br />HSC 25290.1(e) <br />VPH monitoring of the interstitial spaces of the UST system is not maintained <br />306 <br />CCR 2630(d) <br />Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity <br />307 <br />CCR 2632(c) <br />Monitoring system of the interstitial space of a double walled system not maintained <br />308 <br />CCR 2636(f) <br />Failed to maintain a continuous monitoring system that activates an audible and visual alarm <br />309 <br />CCR 2636(f)(1) <br />Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC <br />310 <br />CCR 2636(f)(1) <br />Sensor in a turbine sump failed to activate an audible and visual alarm or stop the flow product <br />311 <br />CCR 2636(f)(5) <br />Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs <br />312 <br />CCR 2636 <br />Failed to properly program or operate leak detection equipment <br />313 <br />CCR 2638(f) <br />Failed to affix a tag sticker on monitoring equipment certified, repaired, or replaced <br />314 <br />CCR 2631(a) <br />Primary containment not tight (pre -Jul 2003) <br />315 <br />HSC 25290.2(c)(1) <br />Primary containment not tight (Jul 2003-Jun2004) <br />316 <br />HSC 25290.1(c)(1) <br />Primary containment not tight (after Jun 2004) <br />317 <br />HSC 25290.1, 25290.2, <br />Secondary containment not tight <br />25291 <br />318 <br />CCR 2636(x) <br />Failed to have secondary containment <br />319 <br />HSC 25291(e) <br />Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003) <br />320 I HSC 25290.1(c3), I Secondary containment not constructed to prevent water intrusion <br />Page 2 of 6 <br />201 <br />■V ■R ❑COS <br />❑V ❑R ACOS <br />D ❑R ii COS <br />❑V ii aCOS <br />❑V c Li COS <br />ii c ❑COS <br />❑V ii ❑COS <br />❑V ii ❑COS <br />■V w ❑COS <br />aV c Li COS <br />oV ❑R ❑COS <br />❑V ❑R Li COS <br />L)V <br />❑R <br />❑COS <br />aV <br />❑R <br />❑COS <br />❑V <br />❑R <br />_,COS <br />DV <br />❑R <br />❑COS <br />D <br />c <br />Li COS <br />■V <br />■R <br />■COS <br />o n ❑COS <br />❑ V R ❑ COS <br />❑V ii ii COS <br />❑V EiR ❑COS <br />oV ❑R ❑COS <br />❑V c ❑COS <br />❑ V ❑ R COS <br />❑V ❑R ❑COS <br />❑V E ❑COS <br />❑V u L, COS <br />n ii aCOS <br />ii ❑R ❑COS <br />■V ■R ❑COS <br />❑V ❑R ❑COS <br />