My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
COMPLIANCE INFO_2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:13 PM
Creation date
11/5/2018 8:25:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4943\PR0506488\COMPLIANCE INFO 2013 TO 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
232
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1 868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sigov.or /g ehd <br /> U'N'DERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility7 Eleven #32190A Address <br /> 4943 S Hwy 99 Stockton CA 95215 Datpeectlon <br /> Name: May 13, 2014 <br /> reses s' <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Safe[ Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation,C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (Mi) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 19.84) (M�i <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> GLASS I,CLASS II,or MINOR-Notice to Comply) <br /> On site to conduct a routine inspection and witness the annual monitoring system certification testing. <br /> 109. Annual monitoring system certification, leak detector testing, and spill container testing was <br /> performed on 5-23-13 and a test report has not been submitted to the EHD. A copy of the test report <br /> must be submitted within 30 days of the tests. Immediately submit a copy of the test report to the EHD. <br /> 205. Nirmaljit Badial stated that he was hired in 2007. Vanessa Coss was hired approximately 13 <br /> months ago. The documentation for the employees trained by the designated operator does not indicate <br /> these employees' hire dates. The designated operator shall train facility employees for which he or she <br /> is responsible in the proper operation and maintenance of the UST system once every <br /> 12 months. The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br /> A list of facility employees who have been trained by the designated UST operators(s) shall be <br /> maintained on-site or off-site at a readily available location, if approved by the local agency. The list shall <br /> be provided to the local agency upon request. The list shall include the dates of training for all facility <br /> employees, and the hiring dates for all facility employees hired on or after July 1, 2005. Ensure that <br /> employees have been trained by the designated operator, maintain the correctly completed list on site, a <br /> and submit a copy of the training records to the EHD by 6-13-14. <br /> 204. The designated operator failed to check and note the correct test dates for the monitoring system <br /> and spill container tests on the 4-15-14 designated operator monthly inspection report. These tests <br /> were listed as 5-23-14. These tests should have been listed as 5-23-13. During the monthly inspection, <br /> the designated operator shall check that all required testing and maintenance for the UST system have <br /> been completed and document the dates they were done. Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports. <br /> Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br /> each violation was corrected, including supporting documentation, by June 13, 2014. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector Received By Title, <br /> EHD 23-02 Rev 04/19112 Page 3 USF INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.