2300 - Underground Storage Tank Program
>
PR0506488
>
COMPLIANCE INFO_2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:13 PM
Creation date
11/5/2018 8:25:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4943\PR0506488\COMPLIANCE INFO 2013 TO 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
232
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.s4gov.orglehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Dame: TFacility Address: Date: <br /> 7-ELEVEN INC #32190 Stockton <br /> File Review <br /> 126 HSC 25404(,)(4) Failed to report program data electronically u V u R -i COS <br /> Can Site Records <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions •V D R c COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 112 years o V D R o COS <br /> 203 CCR 2712(b) Failed to maintain records of monitoring,repair, lining,and upgrades on site ❑V D R o COS <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site D V D R n COS <br /> 205 CCR 2712(i) Operating permit not on site u V ❑R D COS <br /> 206 HSC 25294,25295 Failed to record or report unauthorized release in appropriate time frame o V o R ❑COS <br /> 207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed n V n R ❑COS <br /> 208 CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months ❑V ❑R ❑COS <br /> 209 CCR 2715(f) Designated operator employee training not performed or log not kept ■V D R u COS <br /> 210 CCR 2715(f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD D V D R ❑COS <br /> 211 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept u V D R c COS <br /> 212 HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept ❑V u R D COS <br /> UST System Observations <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills u V D R D COS <br /> 302 HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003) ❑V D R D COS <br /> 303 HSC 25290.2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 2003-Jun 2004) ❑V o R ❑COS <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004) D V n R ❑COS <br /> 305 HSC 25290.1(e) VPH monitoring of the interstitial spaces of the'UST system is not maintained D V D R ❑COS <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity ■V D R ■COS <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained o V ❑R ❑COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm ❑V D R D COS <br /> 309 CCR 2636(f)(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC n V D R D COS <br /> 310 CCR 2636(f)(1) Sensor in a turbine sump failed to activate an audible and visual alarm or stop the flow product ❑V D R n COS <br /> 311 CCR 2636(f)(5) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs D V D R ❑COS <br /> 312 CCR 2636 Failed to properly program or operate leak detection equipment n V ❑R n COS <br /> 313 CCR 2638(f) Failed to affix a tag sticker on monitoring equipment certified,repaired,or replaced D V L7 R n COS <br /> 314 CCR 2631(a) Primary containment not tight(pre-Jul 2003) n V ❑R u COS <br /> 315 NSC 25290.2(c)(1) Primary containment not tight(Jul 2003-Jun2004) D V D R D COS <br /> 316 HSC 25290.1(c)(1) Primary containment not tight(after Jun 2004) u V n R D COS <br /> 317 HSC 25290.1,25290.2, Secondary containment not tight u V D R D COS <br /> 25291 <br /> 318 CCR 2636(a) Failed to have secondary containment ❑V u R ❑COs <br /> Received by Inspector: Phone: Date: <br /> (initial): S , ELENA MANZO, REH (209) 953-7699 05101!2015 <br /> Page 2 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.