Laserfiche WebLink
MON RING SYSTEM CERT17FICATION <br /> CERTIFICATION/TEST DATE: Se tember 2, 2014 <br /> Al. FACILITY A2. OWNER <br /> Name 7-Eleven Market#23681 Store#32190 Name 7-Eleven, Inc <br /> Address 4943 South Stale Route 99,Stockton,CA 95206 Address P.O.Box 711,Dallas,TX 75221 <br /> Phone# 209-939-0679 Phone 805-523-2949 <br /> Contact Stephen Boyd Contact Stephen Boyd <br /> D. RESULTS OF TESTING/SERVICING <br /> Make/ Model of Monitoring System: Veeder-Root TILS-350 SN# <br /> Software Version Installed: <br /> Complete the following checklist: <br /> F <br /> Yes ❑ No" Is the audible alarm operational? <br /> Yes ❑ No" Is the visual alarm operational? <br /> FYes ❑ No* Were all sensors visually Inspected,functionally tested,and confirmed operational? <br /> ❑ Yes ❑ No' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their proper operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station,Is all communications equipment(e.g.modems) <br /> ❑ N/A operational? <br /> ❑ Yes ❑ No* For pressurized piping systems,does the turbine automatically shut down If the piping secondary containment <br /> i <br /> ❑ NIA monitoring system detects a teak,fails to operate,or Is electrically disconnected? It yea:which sensors initiate <br /> positive shutdown? (check all that apply) ❑ Sump/Trench sensors; ❑ Dispenser Containment Sensors. <br /> ❑ Yes ❑ No* Did you confirm positive shut-down due to leaks and sensor failureldiseonnection? <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> ❑ N/A mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? % <br /> ❑ Yes* ❑ No was any monitoring equipment replaced? If yes,identity specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑ Yes* ❑ No Was any liquid found Inside any secondary containment systems designed as dry systems? <br /> (Check all that apply) ❑ Product; ❑ Water. if yes,describe causes in Section E,below. <br /> ❑ Yes ❑ No' Was monitoring system set-up reviewed to insure proper settings? Attach set-up reports,If applicable. <br /> ❑ Yes ❑ No* I Is all monitoring equipment operational par manufacturer's specifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. COMMENTS <br /> 02014 Walton Engineering,Inc. <br /> Page 2 of 3 <br />