Laserfiche WebLink
STATE OF CALIFORNI6 WATER RESOURCES CONTR OARD ;'` •° '"'. <br /> `� <br /> FORM `B': UNDE GROUT D STORAGE <br /> TANIINFORMATION RAM <br /> TANK TANK PERMIT COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> ❑ 1 NEW PERMIT F--] 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> MARK ONLY <br /> ONE ITEM 112 INTERIM PERMIT F-14 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE �8 TANK REMOVED L71 <br /> Time TimOil 30155 N3V D M7 -YES❑ NO N <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: o 00 <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY OO <br /> A. OWNERS TANK ID# 3900000-1208000002 B. MANUFACTURED BY'. <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED n, LEADED 3 DIESEL <br /> ❑ <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL 0 1 PRODUCT ❑ 4 GASAHOL 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF C.A.S.N: <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑ 1 DOUBLEWALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM ® 2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ® 1 STEEUIRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑ 6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑ 8100%METHANOL COMPATIBLE FRP <br /> MATERIAL ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑99 OTHER <br /> ❑ 1 RUBBER LINED ,,�❑� 2 ALKYD LINING E] 3 EPDXY LINING 4 PHENOLIC LINING <br /> C. INTERIOR ❑ 5 GLASS LINING �J 6 UNLINED ❑ 95 UNKNOWN <br /> LINING <br /> ❑ IS LINING MATERIAL COMPATIBLEWITH 100%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> 0. CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TAR OR ASPHALT ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINEDTRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> ®1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U B 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1 VISUALCHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUNDWATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P 5 7 PRESSURETESTING MS 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(M0/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH I�I <br /> -1S1L <br /> SUBSTANCE REMAINING IN INERT MATERIAL? ❑YES aRO <br /> AUJgUSt 1978 GALLONS ` <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED NAT DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY N JURISDICTION M AGENCY# FACILITY ID# TANK ID# <br /> CURRENT LOCAL AGENCY FACILITY ID N APPROVED BY NAME PHONE M WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK X PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT N BY: <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPAN01I FACILITY/SITEDATA PPR TION, NOGRM 'A',UNLESS A b RENT FORMA' HAS BEEN FILED <br />