BILLING 1985 - 2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
O
>
O
>
132 (HWY 132)
>
2393
>
2300 - Underground Storage Tank Program
>
PR0231594
>
BILLING 1985 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2024 1:12:44 PM
Creation date
11/5/2018 10:18:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985 - 2007
RECORD_ID
PR0231594
PE
2351
FACILITY_ID
FA0003586
FACILITY_NAME
VERNALIS ORCHARD FUEL
STREET_NUMBER
2393
Direction
E
STREET_NAME
HWY 132
City
VERNALIS
Zip
95385
APN
25525007
CURRENT_STATUS
02
SITE_LOCATION
2393 E HWY 132
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\O\HWY 132\2393\PR0231594\BILLING 1985 - 2007.PDF
QuestysFileName
BILLING 1985 - 2007
QuestysRecordDate
2/21/2018 5:18:53 PM
QuestysRecordID
3803053
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS 51593 Z' <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 PC;-3Sv <br /> (Two pages per tank) <br /> oe Page-3-of <br /> TYPE OF ACTION 70 1.NEW PERMIT ❑ 4.AMENDED PERMIT ❑ 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one item only) ❑ 3.RENEWAL PERMIT ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specify reason) ❑ 8.TANK REMOVED <br /> BUS E S NAME(Same as FACILITY NAME or DBA-Doing Business As) 3. FACILITY ID: 1. <br /> WAM <br /> u�Lsu <br /> LOCATION WITHIN SITE(Optional) 431 <br /> I.TANK DESCRIPTION <br /> (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 2 I ` h/4 TANK MANUFACTURER 433. COMPARTMENTALIZED TANK ❑Yes ❑ No 434. <br /> C-/)S 1, 7 `t_✓ ,J O ?- If"Yes;'complete one page for each compartment. <br /> DATE INSTALpLED p` 435. TANK CAA,P,ACITY IN GALLONS 436. NUMBER OF COMPARTMENTS <br /> (YEA"O) L�✓U '✓fM�' 21 437, <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II.TANK CONTENTS <br /> TAAIK USE 439 PETROLEUM TYPE 44II <br /> 'f1. MOTOR VEHICLE FUEL '�%REGULAR UNLEADED �❑//2. LEADED ❑5. JET FUEL <br /> (If checked,complete Petroleum Type) IIIb. PREMIUM UNLEADED '1'3. DIESEL 06. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM EvIc. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441. CAS#(from Hazardous Materials Inventory page) 442. <br /> ❑ 4. HAZARDOUS WASTE <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑1. SINGLE WALL ❑3. SINGLE WALL WITH EXTERIOR ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) �/ MEMBRANE LINER C395. UNKNOWN <br /> u DOUBLE WALL ❑4. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank 1. BARE STEEL -03. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS E-18. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC FRP W/100%METHANOL <br /> TANK MATERIAL-secondary tank ❑ I. BARE STEEL V3. FIBERGLASS/PLASTIC ❑8. FRP COMPTIBLE W/100%METHANOL ❑95.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS [19. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑,,YY GLASS LINING El 95.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING El 4.PHENOLIC LINING �6.UNLINED ❑99.OTHER <br /> Check one item only) <br /> OTHER CORROSION ❑1.MANUFACTURED CATHODIC 3.FIBERGLASS REINFORCED PLASTIC ❑95.UNKNOWN 449. DATE INSTALLED 449. <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT ❑99.OTHER <br /> If A licable ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFIL,,L,,,,,,(( YEAR INSTALLED 450. YP r 451. F2. <br /> FILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) 1.SPILL CONTAINMENT vuo. ALARM 0 3.FILL <br /> M.DROP TUBE BALL FLOAT ❑4.EXEMPT E SHUT OFF VALVE <br /> 3.STRIKER PLATE <br /> IV.TANK LEA&DETECTION <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453. IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑ VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> �J 2. AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE ❑2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG [:17.GROUNDWATER ❑3.MANUAL MONITORING <br /> [14.STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99. OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456, TANK FILLED WITH INERT MATERIAL? 457. <br /> gallons ❑Yes ❑ No <br /> UPCF hwfWrc-b(1/99)-1/4 www.unidoes.org Rev.02/16/00 <br />