Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> y 'OVIRONMENTAL HEALTH DEPARTMENT <br /> 304 East Weber Avenue,3rd Floor,Stockton,CA 95202 08 <br /> Wehd <br /> Telephone:(209)468-3420 Fax: (209)468-3433 Web: www.s' ov.or <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT nated Operator- Inspection Dale: <br /> Facility nam8e. I V, (D <br /> ft4 <br /> usy#, <br /> Facility address: <br /> c' aProduct <br /> Ph <br /> Facility ConTitle: one: <br /> tact: r <br /> Overrill prevention: <br /> Monitoring Panels Pi ing system: !:� <br /> tfvtechanical ❑Audible/visual <br /> L Pressurized fl SuctionE3ravit <br /> Violations: <br /> Inspection type: <br /> ❑MI-RDetect ❑M2-RPrev ❑M-3 Both <br /> outine N#vlonitoring Certification ❑Installation ❑Other V R <br /> # Code Section VIOLATION(S) HSC–Califomia Health&Safety Code;CCR–California Code of Regulations V <br /> V–Violation;RV–Repeat Violation <br /> 1 HSC 25284 Permit too erate <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 (b)&(c) Current Unified Pro ram Consolidated Forms on file with EF <br /> (Facility and tank form <br /> 4 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632 c (2) D) Monitorin &res onse olan is current and filed with the local agency <br /> 6 CCR 2712(i) Monitoring k response Dian is onsite MI <br /> 7 CCR 2712 b) Maintenance&monitoring records <br /> 8 CCR 2643 (d) Dail monitoring of suction piping(pre-January, 1, 1984) <br /> 9 HSC 25292.1 UST s stem isoperated to prevent unauthorized release M1 <br /> 10 CCR 2632 c)(2 UST monitoring system is present M1 <br /> 11 CCR 2630 d) UST s stem monitorin equipment is properly located to detect a leak M2 <br /> 12 HSC 25291 UST s stem monitoringequipment iso erational M1 <br /> 13 CCR 2636 f) 1 Continuous monitoringsystem for underground i in &UDC is resent <br /> 14 CCR 2631 (a) Primary containment is product tight <br /> 15 HSC 25291 (a(2) Secondary containment for UST is tight <br /> , 16 CCR 2636 c 1) All releases in secondary pipingflow to a collection sump (M1) <br /> 17 HSC 25291 (f) Line leak detectors are installed (M2 <br /> 18 CCR 2635 b)(1) Spill container M2 <br /> 19 CCR 2635 b 2) Overfill prevention s stem <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoring <br /> &2°containment <br /> 21 HSC 25291 (e) Water in 21 containment analyzed&properly disposed of Ml <br /> 22 CCR 2650 Recording/reponing of unauthorized releases <br /> 23 CCR 2715 Desi nated operator: (a)Statement from UST owner; (c-e)Monthly inspection;(fJ Em to ee trainin <br /> 24 CCR 2638 a Annual monitorine certification M] <br /> 25 CCR 2638(a) Annual line leak detector test <br /> 26 HSC 25284.2 Annuals ill containment—'.- M1 <br /> 27 CCR 2636 (4 Annual line tightness test (M2 <br /> 28 CCR 2661 (9 Repair for tank/piping has had ti mess test <br /> 29 CCR 2643 a Biennial ti htness test ofgravity i in re-Januar 1, 1984 <br /> 30 CCR 2643 d) Triennial line test for conventional suction piping(pre-January 1, 1984 (M1 <br /> 31 HSC 25292.5 Double walls stem located within 1000' of Public well-ELD <br /> 32 CCR 2661 Permit to re air UST system <br /> 33 HSC 25286(a) Permit to alter monitoring system <br /> 34 HSC 25298(b) Permit to teTporarily temporarilyclose UST system <br /> 35 HSC 25298 c Permit to close UST system <br /> 36 HSC 25299(a)(9) Disabling leak detection devices <br /> 37 HSC 25298 a) Illegal abandonment of UST system <br /> 38 Other: i <br /> E INSPEC OR: PFIOtiE: <br /> >Oths <br /> 2 <br /> R EIVED BY: TITLE: Recce' er than sanitary waste <br /> methods: <br /> Dry s/French Drains <br /> FHD 23-02-002 <br />