COMPLIANCE INFO 1988 - 2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PALM
>
11651
>
2300 - Underground Storage Tank Program
>
PR0503314
>
COMPLIANCE INFO 1988 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:16 AM
Creation date
11/6/2018 10:05:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1988 - 2011
RECORD_ID
PR0503314
PE
2381
FACILITY_ID
FA0005798
FACILITY_NAME
SOUTHWEST HIDE COMPANY
STREET_NUMBER
11651
STREET_NAME
PALM
STREET_TYPE
LN
City
RIPON
Zip
95366
APN
22809005
CURRENT_STATUS
02
SITE_LOCATION
11651 PALM LN
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PALM\11651\PR0503314\COMPLIANCE INFO 1988 - 2011.PDF
QuestysFileName
COMPLIANCE INFO 1988 - 2011
QuestysRecordDate
1/27/2018 12:54:04 AM
QuestysRecordID
3775323
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATEIOFCAUFORNIA <br /> GEORGE DEUKMEJIAN,Governor <br /> CALIFORNIA REGIONAL WATcn QUALITY CONTROL BOARD— <br /> CENTRAL VALLEY REGION <br /> 3443 ROUTIER ROAD <br /> SACRAMENTO,CA 95827-3098 ! 1 <br /> 18 March 1988 V.- <br /> VSA � <br /> n . <br /> ENV1R�Al!SERV GESTH <br /> Mr. Dana Means FER <br /> Southwest Hide Company <br /> P.O. Box 2083 <br /> Manteca, CA 95336 <br /> REVISED GROUND WATER MONITORING PROPOSAL; SAN JOAQUIN COUNTY <br /> We have reviewed the subject proposal dated January 1988. Overall , the next phase <br /> of proposed work is adequate. We do have, however, a number of comments regarding <br /> the workplan which we discussed with you and your consultants at a meeting on 8 <br /> March 1988 (sign-up sheet enclosed) . The comments are as follows: <br /> 1. Water levels need to be presented and contoured on a plan map of the site and <br /> surrounding area. Water levels should be measured at least twice monthly. <br /> 2. A new time schedule for completing work needs to be submitted. The existing <br /> one is out of date. <br /> 3. Details regarding drilling methods, past and proposed logging procedures, <br /> monitoring well materials and construction techniques, development methods, <br /> and purging/sampling protocol need to be submitted. <br /> 4. Proposed well locations should be presented on a site plan with appropriate <br /> identification. Wells screened at different depths to define vertical <br /> gradients and contamination need to be completed at single locations in <br /> clusters. <br /> 5. . Laboratory methods should be identified by method numbers; include QA/AC. <br /> 6. Screen intervals of deep monitoring wells must be based on the stratigraphy <br /> encountered. <br /> 7. The proposed soil sampling locations should be adjusted or reduced based on <br /> previous sampling results. <br /> 8. Future report submittals should contain an introduction and summary of project <br /> status, description of work performed, presentation of data. discussion and <br /> interpretation of results, recommendations for additonal work (if any' , with <br /> an accompanying time schedule. All data, including QA/QC results, should be <br /> summarized in tables. Actual results, logs field sheet; etc. should be <br /> appendicized. <br />