Laserfiche WebLink
.ri San Joaquin County now <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: vdww.sjgov.oro/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />11NG AVE STOCKTON <br />Date: <br />March 04 2015 <br />File Review <br />126 <br />HSC 25404(e)(4) <br />Failed to report program data electronically <br />o V o R o COS <br />On Site Records <br />201 CCR 2712(b) Failed to maintain alar logs and/or records of follow up actions o V D R c COS <br />202 CCR 2712(b) Faded to maintain cathodic protection test records on site for at least 6 1/2 years o V c R o COS <br />203 CCR 2712(b) Failed to maintain records of monitoring, repair, lining, and upgrades on she o V c R c COS <br />204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site c V c R c COS <br />205 CCR 2712(1) Operating peril not on site u u DCOS <br />206 HSC 25294, 25295 Failed to record or report unauthorized release in appropriate time frame o V D R c COS <br />207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed o V c R D COS <br />208 CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months D V c R o COS <br />209 CCR 2715(f) Designated operator employee training not performed or log not kept D V o R c COS <br />210 CCR 2715(f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD D V o R D COS <br />211 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept D V o R c COS <br />212 HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept V o R n COS <br />UST System Observations <br />301 <br />HSC 25292.1 <br />UST system is not operated to prevent unauthorized release, including spills and overfills <br />o V c R D COS <br />302 <br />HSC 25291(b) <br />UST system incapable of detecting leak from primary into secondary containment (pre-Jul 2003) <br />o V D R o COS <br />303 <br />HSC 25290.2(d) <br />Monitoring system not maintained to detect entry into secondary containment (Jul 2003-Jun 2004) <br />c V D R o COS <br />304 <br />HSC 25290.1(d) <br />Monitoring system not maintained to detect entry into secondary containment (after Jul 2004) <br />o V D R c COS <br />305 <br />HSC 25290.1(a) <br />VPH monitoring of the interstitial spaces of the UST system is not maintained <br />o V c R D COS <br />306 <br />CCR 2630(d) <br />Monitoring equipment is not installed or maintained to detect a leak at the eadiest opportunity <br />D V c R o COS <br />307 <br />CCR 2632(c) <br />Monitoring system of the interstitial space of a double walled system not maintained <br />o V D R D COS <br />308 <br />CCR 2636M <br />Failed to maintain a continuous monitoring system that activates an audible and visual alarm <br />D V c R o COS <br />309 <br />CCR 2636(f)(t) <br />Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC <br />D V o R D COS <br />310 <br />CCR 2636(f)(1) <br />Sensor in a turbine sump failed to activate an audible and visual alarm or stop the flow product <br />c V D R o COS <br />311 <br />CCR 2636(f)(5) <br />Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs <br />D V D R o COS <br />312 <br />CCR 2636 <br />Failed to properly program or operate leak detection equipment <br />D V o R o COS <br />313 <br />CCR 2638M <br />Failed to affix a tag sticker on monitoring equipment certified, repaired, or replaced <br />o V o R D COS <br />314 <br />CCR 2631(a) <br />Primary containment not fight (pre-Jul 2003) <br />c V DR D COS <br />315 <br />HSC 25290.2(c)(1) <br />Primary containment not fight (Jul 2003Jun2004) <br />c V o R o COS <br />316 <br />HSC 25290.1(c)(1) <br />Primary containment not tight (after Jun 2004) <br />o V c R D COS <br />317 <br />HSC 25290.1, 25290.2, <br />25291 <br />Secondary containment not light <br />o V o R o COS <br />318 <br />CCR 2636(a) <br />Failed to have secondary containment <br />D V o R D COS <br />Received by <br />(initial): <br />Inspector. <br />FATINAH ZAREEF, REHS <br />Phone: <br />(209) 953-7311 <br />pate: <br />03/04/2015 <br />Page 2 of 4 <br />