COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4445
>
2300 - Underground Storage Tank Program
>
PR0231785
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 12:46:20 PM
Creation date
11/6/2018 10:18:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231785
PE
2361
FACILITY_ID
FA0003994
FACILITY_NAME
PERSHING GAS FOR LESS
STREET_NUMBER
4445
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11018006
CURRENT_STATUS
01
SITE_LOCATION
4445 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PERSHING\4445\PR0231785\COMPLIANCE INFO\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
10/17/2016 4:41:09 PM
QuestysRecordID
3177280
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s*gov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />PERSHING GAS <br />Facility Phone: <br />(209) 477-8004 <br />Date: <br />January 30, 2017 <br />Facility Address: <br />4445 N PERSHING AVE, STOCKTON, CA 95207 <br />CERS ID: <br />10181565 <br />Inspection Contract: <br />Daljit Singh <br />Title: <br />Owner <br />Phone: <br />(2 09) 277-8004 <br />Inspection Type: <br />ROUTINE INSPECTION - Operating Permit <br />Program: <br />2361 - UST FACILITY <br />Consent For: <br />0 Inspection 21 Photos Z Sam les <br />I Consent Given By: <br />I Daljit Singh, Owner <br />Service Technician Onsite: Exp. Date: <br />David Winkler 03/01/2018 <br />Designated Operator: Exp. Date: <br />David Winkier 02/2612018 <br />Service Technician Manufacturer's Training <br />Veeder Root, 02/03118; VMI, 11113/17; Tank Tester,03/31/17 <br />GCR = California Code of R&qL113fiCns HSC = Health and SafetyCo8e CFR = Code of Federalegu a ions <br />V - Violation R =Repeat violation COS = Corrected on site during inspection <br />File Review <br />101 <br />HSC 25284 <br />No permit to operate <br />■ V ❑ R ❑ COS <br />102 <br />HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />❑ V n R ❑ COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />■ V n R ❑ COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />■ V o R ❑ COS <br />105 <br />CCR 2632(d)(1) <br />Failed to have an approved UST monitoring plan <br />■ V ❑ R ❑ COS <br />106 <br />CCR 2632(d)(2) <br />Failed to have an approved UST response plan <br />■ V ❑ R ❑ COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />■ V o R o COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />n V n R o COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />o V o R n COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />n V n R n COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />■ V n R n COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />n V ❑ R ❑ COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />o V o R u COS <br />114 <br />CCR 2636(f <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />r V ❑ R ❑ COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of designated operator identification or change within 30 days <br />■ V ❑ R ❑ COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />u V ❑ R ❑ COS <br />117 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />n V n R ❑ COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />❑ V o R o COS <br />119 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />o V ❑ R n COS <br />120 <br />CCR 2635(d) <br />Failed to submit UST Certification of Instal lationlMod ification <br />❑ V o R ❑ COS <br />121 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />o V o R ❑ COS <br />122 <br />CCR 26310) <br />Failure to submit UST system component statement of compatibility for substance stored <br />[ r V o R a COS <br />On Site Records <br />201 <br />CCR 2712(b) <br />Failed to maintain alarm logs and/or records of follow up actions <br />❑ V ❑ R o COS <br />202 <br />CCR 2712(b) <br />Failed to maintain cathodic protection test records on site for at least 6 112 years <br />c V o R o COS <br />FA0003994 PR0231785 SCO01 01/30/2017 <br />EHD 23-01 Rev. 09122116 Page 1 of 7 Underground Storage Wank Program OiR <br />
The URL can be used to link to this page
Your browser does not support the video tag.