My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4445
>
2300 - Underground Storage Tank Program
>
PR0231785
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 12:46:20 PM
Creation date
11/6/2018 10:18:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231785
PE
2361
FACILITY_ID
FA0003994
FACILITY_NAME
PERSHING GAS FOR LESS
STREET_NUMBER
4445
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11018006
CURRENT_STATUS
01
SITE_LOCATION
4445 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PERSHING\4445\PR0231785\COMPLIANCE INFO\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
10/17/2016 4:41:09 PM
QuestysRecordID
3177280
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />4. TANK ANNULAR TESTING <br />Page of <br />Test Method Developed By: ❑ Tank Manufacturer ❑ Industry Standard -' Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum Hydrostatic <br />11 Other (Spec) <br />Test Equipment Used: <br />Equipment Resolution: <br />4' <br />Tank 4 I "Tank # 2 Tank # 3 Tank # 4 <br />Is Tank Exempt From Testing?' <br />Yes <br />Yes <br />Yes <br />Yes <br />Tank Capacity: <br />12K <br />12K <br />12K <br />500 Gallon <br />Tank Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Tank Manufacturer: <br />Owens Corning <br />Owens Corning <br />Owens Corning <br />Owens Corning <br />Product Stored: <br />Super 91 <br />Diesel <br />Regular 87 <br />Used Oil <br />Wait time between applying <br />vacuum and starting test: <br />*See Comments <br />*See Comments <br />*See Comments <br />*See Comments <br />Test Start Time: <br />Initial Reading (Ri): <br />Test End Time: <br />m <br />Final Reading (RF): <br />Test Duration: <br />AN <br />N 2 '� �ti e <br />Change in Reading (RF -Rt): <br />Pass/Fail Threshold or Criteria: <br />ENVIRONMENTAL <br />HEAU H <br />Test Result: <br />DEPARTMENT <br />Was sensor removed for testing? <br />Was sensor properly replaced and <br />verified functional after testin-=? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Tanks have Brine Filled Annulars, and are exempt from Periodic Testing. <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. (California Code of Regulations, Title 23, Section 2637(a)(6)1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.