Laserfiche WebLink
kaiI4 <br />61fl, <br />aDAAC OF TRUSTEES SAii-, JOAQUIN LOCAL HEALTH DISTMiCT <br />Jamoe Culbertson, Prof. <br />tERViNO <br />Peirlcle E. Vannuccl, Secy. - <br />Tommy Joyce 1601 East Hazelton Avenue, P. O. Box 2009 <br />City of Lodi <br />San Joaquin County <br />Earl Plmenlsl Stockton, California 95201 <br />City of Escolon <br />:ern Sucbee <br />City of Manteca <br />Daniel L. Flores 209/48"781 <br />City of Rlpon <br />John D. Mut, M.D. <br />City of Stockton <br />William J. Wade Joel Khanna, M.O., M.P.M., District Health OfficerCltyof <br />Tracy <br />Loy* Mary Anna Lo <br />San Joaquin County <br />San Joaquin County <br />�I `i x-15 � � • �i-�`��t i f�(C� <br />TO: INSTALLERS AND OWNERS OF NEW UNDERGROUND STORAGE TANKS <br />The Environmental Health Division has established the following <br />guidelines to assist <br />you in the completion of your construction project. The guidelines <br />specify the <br />construction and monitoring details needed to complete our review of your underground <br />storage tank system. <br />I. SUBMITTAL OF PLANS <br />a. Submit 4 complete sets of detailed drawings to the Environmental Health Division. <br />One set will be retained by the department. <br />b. Include equipment specification sheets and manufacturer's <br />brochures <br />describing operating and monitoring systems. <br />c. Include detailed monitoring and response plans. <br />2. PLAN REVIEW AND OPERATING PERMIT FEES <br />a. New facility plan review fee of $30.00 and operating permit application fee <br />Of $150.00 plus $50.00 per additional tank is due at time of plan submittal <br />plus $56.00 per tank State surcharge. <br />b. New installation of additional tank at existing facility is $30.00 plan review <br />plus $50.00 per new tank permit fee plus State Surcharge. <br />3. PLAN REVIEW GUIDELINES <br />a. The enclosed plan review sheet is provided for your information to assist you <br />in interpreting our requirements for new tank systems. <br />b. A letter will be sent to you in the event deficiencies are found in the tank plans. <br />c. A copy of the California Underground Storage Tank Regulations can be obtained <br />from the State Water Resource Control Board 916-324-1262 or from this office <br />for a handling fee of $2.00. <br />d. Please check with the San Joaquin County Air Pollution Control District, <br />Building Department and Fire District for their requirements. <br />e. Submittal of new tank plans to this agency satisfies tank registration <br />requirements for the State of California. <br />f. Please allow five (5) to fifteen (15) working days for plan review. <br />g. Field inspections associated with the plan review process should be arranged <br />twenty-four (24) hours in advance. <br />h. A total of three (3) inspections will be made of the tank system being installed <br />according to the enclosed inspection record. <br />i. Complete and submit an application to operate underground storage tank(s). <br />1111 23 050 8/86 <br />