Laserfiche WebLink
SAN JOAQUIN C( NTY ENVIRONMENTAL HEA, H DEPARTMENT <br /> UST WORKSHEET FOR SITE CLOSURE EVALUATION <br /> DATE: -1 ' <br /> I. FACILITYITANK INFORMATION <br /> STATUS CODE: <br /> SITE/FACILITY NAME: <br /> ADDRESS: e(_Shin LX- CITY: S�a�K <br /> FAM F <br /> PRPR* O -I 5 TANK# 39 �D <br /> FA <br /> TANK SIZE: �JFJO Ion FUEL TYPE: O 1 <br /> II. GENERAL SITE HISTORY <br /> Is Permit Current? at Yes ❑ No ❑ NA Documented Soil/GW Contamination?"' ❑ Yes' No <br /> Type of Tank❑Steel (Fiberglass ❑Single <br /> Number of Tanks at Facility Age of Tanks(if available) pe <br /> III. TANK HISTORY <br /> Was Tank Tested? 691'es ❑No ❑NA Failed Testing? ❑Yes 16 No ❑NA If Yes,Provide Dates: <br /> Was Tank System Repaired?❑Yes No❑NA If Yes,Describe Repair: <br /> ❑BTEX❑TPH-G❑TPH-D ❑LEAD❑EDB <br /> Was Repair Done Under Permit?❑Yes❑ No 0 NA Were Soil Samples Analyzed? ❑Yes No ❑OTHER OX <br /> Type of Failure/Discharge: ❑Catastrophic ❑Long-term Leak ❑Overfill q1 Unknown ❑Other <br /> IV. REMOVAL HISTORY Attach File <br /> Soil Samples Received? es ❑No Seasonal High Depth to GW j�ft bgs Year/Reference q <br /> Onsite and/or Nearby Well(s)? L3 Yes No S S S <br /> ❑ Irrigation: # Distance o Tank_ It C Score 10 C Score 9 <br /> ❑Domestic:# Distance to Tank_ ft 0 points if 0 points if 0 Score 5 points if <br /> ❑ Public: # Distance to Tank_ tt condition is condition is R condition is met <br /> E met E met E <br /> V. SITE FEATURE-LEACHING POTENTIAL ANALYSIS <br /> Minimum Depth to Groundwater from Soil Sample(feet) >100 51-100 25-501 <br /> Fractures in Subsurface(applies to foothill or mountain areas) None Unknown Present <br /> Average Annual Precipitation(14 inches for SJC area) ----- <10 9 10-25 ---- 26-402 <br /> Man-Made Conduits which Increase Vertical Migration ------ None Unknown Present <br /> i.e.septic sstems,water wells, ponds) <br /> Unique Site Features:Recharge Area,Coarse Soil(coarse sands, None At Least One More Than One <br /> ravels), nearbywells <br /> Column Totals Total Points 'd o + + � = 3y <br /> Sample Results for BTEX: Range of Total Points 49 Points or More 41 -48 Points 40 Points or Less <br /> B <br /> T Maximum Allowable BTEX B T E X B T E XN/A3 <br /> E Levels(ppm) 1.0 50 50 50 0.3 0.3 0 1.0 <br /> x P,.3 4 -sao—. -.I <br /> Sample Results for TPH: Maximum Gasoline 1,000 100 10 <br /> N� Allowable TPH <br /> Levels m Diesel 10,000 1,000 100 <br /> Footnotes: —'If documented soil and/or groundwater contamination is present,do not complete leaching potential analysis(i.e.site is already on the contamination list). <br /> 1 If depth is>5 feet and<25 feet,score 0 points. If depth is<=5 feet,do not use table. 2 If precipitation is>40 inches,score 0 points. <br /> 3 Levels for BTEX are not applicable at a concentration of 10 ppm for TPH-Gasoline or 100 ppm forTPH-Diesel. <br /> VI. STAFF RECOMMENDATION/REFERRAL/REVIEW <br /> 1. Are BTEX or TPH Concentrations>Allowable Levels? QYes No 2. If No,Is Site Closure Recommended? iff Yes ❑ No <br /> Completed By: Date Referred to Site Mitigation Unit for incl Actiont Lµ- Z(4 — IT <br /> Reviewed By: .r, Concur with Staff Recommendation 16 Yes ❑ No <br /> Date Closure Letter Mailed tAll Cases are Referred to Site Mitigation for Final Action <br /> EH 23-0080(Rev 11/14/08) <br />