Laserfiche WebLink
r <br /> SURFACE MOUNTED CABLE DUPLEX RECEPTACLE 12 14 4 PLEX LAN CABLES 2 4 IAN CABLES O Y <br /> RETAIL AUTOMATION COMPUTER NOTES ON BACK ROOM WALLS TO BATTERY <br /> (1) PER REGISTER PLUS FUTURE < - <br /> 1, Workstation Table TELEPHONE 2 LINES <br /> GTM—�- 16 2 PLEX FOR CABLES 16 2 DEDICATED COMPUTER MODEM LINE <br /> 2. Retail Automation Computer (CPU) 2 (1) FOR M.O. BATMAN CABLE O '� <br /> _ (1) FUTURE #1 TELEPHONE VOICE LINE <br /> 3. Monitor GAS _ 0 4 n fROMTELEPHONE BOARD <br /> 4. Keyboard CONTROLLER <br /> 5. Printer - -'-' z k <br /> 6. Battery / DL __.[.- - a �. <br /> 7. Router 'i <br /> 3 t; <br /> 8. Hub i t O /� p ___ 9 p' <br /> 9. Modem <br /> 6 �z U <br /> 10. Handheld Cradle <br /> x <br /> 11. Optional fan and task light (served by auxiliary duplex outlet) fr <br /> 7 W <br /> � — 5 �a 1 BACKROOM H = <br /> 12. New duplex receptacle which receives the following plugs; 13 I 106 11 ` 20 <br /> // I I <br /> (1) Battery; (2) Future; 4 9 6 ! I I <br /> 13. Computer battery receptacle will receive the following plugs. See Retail <br /> M <br /> Automaton Workstation elevation this sheet. o T— <br /> (1) CPU: (2) Cradle; (3) Monitor•, (4) Power Strip (Supplied by NCR installer) <br /> 14. The computer will receive four (4) 100 foot category 5 Systimax LAN cables (3 for registers; 1 `, t `, < - - < ,l I 1 <br /> one future) run from sales area registers through a one inch concuit (see _ 1 1 OF 1 .,,,. I SALES <br /> Wiring Diagram this sheet) and terminate ata four outlet cable jack with a 4 FIN. FLR. TRANSFORMER PLUGS _ _ -�- 111 AREA J 1 <br /> outlet faceplate which meets category 5 transmission requirements as --- --• ..-- -- —_._._—_�—____--- --. —_____— V I 1 102 <br /> exemplified by Model MPSIOOBH type with corresponding face plate. __-_—L-- <br /> _ <br /> Sheet E-1.Register LAN cables will sub up out of the floor at each register location. See 26 SIX PLEX STRIP (BY NCR) <br /> 18" 18" <br /> \'\`\ 1 20 <br /> 15. The computer will receive the following additional data cables. 1 <br /> (1) Cheyenne Money Order Cable- Batman cable; (2) Future lottery, safe cables. — —__-- U <br /> te <br /> Data conduit will have RS232 and 0825 connectors. There are two (2) 1/Q NEN/ STORE RETAIL AUTOMATION ---- ----------- —� < <br /> cables from the computer 25 DBA connectors for money order machine. '_ _._. tz <br /> — <br /> `'' `2' (2) WORKSTATiON ELEVATION <br /> Cables will run form the ISP workstation through a one (1) inch conduit <br /> termination at the sales area backwall (see Wiring Diagram this sheet). EF4 NOT TO SCALE z <br /> 20 AMP CIRCUIT <br /> FOR ISP COMPUTER 4 <br /> 16. Telephone lines: Telephone wiring from telephone panel to dual RJ11 4 PLEX <br /> receptacle by telephone subcontractor. Location for receptacle is marked by <br /> electrical subcontractor. Line #1 is telephone voice line from telephone board. <br /> Line $2 is a dedicated computer modem line. 20 AMP CIRCUIT ELECTRONIC EQUIPMENT <br /> Final interface connection to DMARC board is by telephone contractor. FOR POs ��� <br /> REGISTER 20 / / \ PART PLAN <br /> Telephone Contractor will label the DMARC with appropriate LEC and IXC RECEPTACLE / ELECTRICAL PANEL ( aJ ( dj� <br /> circuit carriers. Label line #1 and line #2 at the ISP. � 24 5 E SHEET E-1A <br /> / EF4 SCALE 1/8"a9'-0' T� Q d� <br /> 17. Auxiliary duplex receptacle for fan and light only. / <br /> 5 <br /> 18. One inch PVC in wait for data cables. See notes 14 and 15 above and wiring TELEPHONE WIRING / // Y6 <br /> diagram on this sheet. <br /> \\\ o n 1p <br /> 19. Cheyenne Money Order Machine. See note 15 above and Wiring Diagram <br /> this sheet. / / �� <br /> 20. Point of Sale (POS) register. / �' TELEPHONE PANEL <br /> 23 <br /> 21. Floor mounted 4 plex receptacle with one receptacle accessible ( others <br /> covered with outlet caps similar or equal to Leviton No,12777.) Receptacle / <br /> will be similar or equal to Race Model No. 192 four (4) square outlet box <br /> with a quad cover similar to Race Model No. 807 with two (2) HubellGTM DATA CABLE Z <br /> \\ h yM <br /> Model No. 5252 duplex receptacles. 2-1" CON <br /> a <br /> Receptacles required at each POS register location, Receptacles are part of <br /> 0 20 AMP IDG circuit with separate sub-ups at each register. See Wiring 10 11 12 13 1 z <br /> 4 15 16 \� <br /> Diagram this sheet and sheets E-1 and E-1A of the construction documents. ` <br /> SEE DETAIL ABOVE \ V N a. <br /> 22, Gasoline Tank Monitor cable and future cables for Gas Controller/CRIND <br /> Cables run form device to backroom computer with cables fastened a. U �_ �', <br /> to wall. (Conduit not required). <br /> m o <br /> 23. Telephone panel (see sheet E-1 for location). Local telephone company makes all 1 8tJ' z U <br /> telephone connections. Orders for new telephone lines are, coorinoted by the local market. 7 w o <br /> If local market needs assistance, call 214-828-7942. n. <br /> F_ a <br /> 24. Electrical panels. See Sheet E-1 of the construction documents. 6 <br /> 25. ATM electrical and telephone line by ATM vendor. ISP BACKROOM <br /> 25 <br /> COMPUTER SALES COUNTER <br /> 2 <br /> 26. New 6 plex power strip supplied by NCR installer. C NT LL ATM RJ45 CONNECTOR _ — RJ45 CONNECTOR <br /> GAS CONTROLLER CABLE HOOD - <br /> D825 FEMALE CONNECTOR AT <br /> ISP END AND HOOD D89 MALE <br /> n� CONNECTOR AT GAS CONTROLLER 9 22 ONE LAN CABLE PER REGISTER, 100 FOOT LENGTH wC NO CONNECTORS. <br /> THE RJ45 CONNECTORS WILL BE INSTALLED BY THE NCR INSTALLER. <br /> EXISTING D-BOX CABLE ATM <br /> ON BACK ROOM WALLo 1 WORK STATION .. _ 4 ZO OPT. CASH REGISTER ,y3 <br /> - JR TABLE D825 CONNECTOR 009 CONNECTOR <br /> EXISTING GAS CONTROLL <br /> ---' GASOLINE PAM - - ISDN <br /> D-BOX(S) TS1000 TELEPHONE ONE BATMAN MONEY ORDER CABLE FOR CHEYENNE MONEY ORDER <br /> _ LINE TE 20 CASH REGISTER �2 MACHINE. CABLE INCLUDES CHEYENNE KIT WHICH INCLUDES ONE D89 <br /> 0�1 SEE NOTES 1,2 & 3 �� CONNECTOR FOR THE MONEY ORDER MACHINE AND ONE 0825 CONNECTOR <br /> _ _ FOR THE ISP COMPUTER END WITH A 089 CONNECTOR. THE BATMAN <br /> �ki �. <br /> o �_ ` .��. ISP ///��► - HUB ROUTER /�. CABLE B SHIPPED WITH O ONE CONNECTOR IN PLACE; THE BARE END OF <br /> N - .(/- �- ,y I 18 \ \ 21 IDG REC. 3 THE CABLE IS USED IN PULL THE CABLE AND WILL REQUIRE THE <br /> EXISTING GASOLINE <br /> CRIND CONTROL CABLE(S) `\` BLE RJ45 1 - 3/4' MONEY ORDER CABLE \ CONNECTOR TO 8E PINNED AND INSTALLED. <br /> N FIDEL <br /> CABLE IN TRENCH DISPENSERS CAT 5 CABLE RJ45 \`\ SAFE <br /> TO f DIISPENSOERSE__YT-� -^_- PATCH <br /> LL I CORDS 1 - 3/4' 115V TOG CIRCUIT \, <br /> INC.TO FUTURECH GREG. (j3 <br /> LLL���111IT Q <br /> aT NOTE: MONEY ORDISTER <br /> UER BLE \ 21 IDG REC. �2 yq� <br /> W 1. EXISTING GAS CONTROLLER (GIBARCO MODEL PAM TS7000) FUTURE LOTTERY, SAFE CABLES - QQ CASH REGISTER #1 HOOD D625 HOOD DB9 <br /> FEMALE CONNECTOR MALE CONNECTOR 3 <br /> o WILL REQUIRE ONE OF THE FOLLOWING CHANCES: TSP END IBACKROOM' <br /> A. A NEW FIRMWARE CHIP TO BE PLACED 19 MONEY ORDER DATE: 15JUL97� <br /> IN THE GAS CONTROLLER <br /> A 21 IpG REG. st <br /> B. A BOARDNDDITION PLACED - 14 3 - 3/4' CONDUIT LAN BLEs ONE GAS CONTORLLER CABLE PROJECT NO. <br /> IN THE EXISTING GAS CONTROLLER <br /> C. 91 A NEW GAS CONTROLLER WITH THE 0825 GASOLINE TANK 3010,20 <br /> NEW CHIP AND BOARD. FEMALE CONNECTOR MONITOR - MSP <br /> BACKROOM DRAWN <br /> 2. PETROLEUM SYSTEM CONVERSION WALK-THRU <br /> FORM WILL BE PERFORMED BY THE ASC <br /> 3. INSTALLATION OF THE GAS CONTROLLER CHANGES AND RETAIL AUTOMATION - LABEL THIS END OF' CABLE APPROVED: <br /> NEW GAS CONTROLLER CHIP, BOARD AND CABLE, WILL NEW STORE WITH INDELIBLE INK AS GTM INSTALLATION OF CABLE . MALE PINS TO BE CONNECTED CL <br /> BE BY ASC CERTIFIED SOUTHLAND GAS MAINTENANCE (T <br /> IN THE BLE COVER ELECTRICAL. CONTRACTOR. EL Ders HOOD 0Y <br /> CONTRACTOR. ( COMPUTER WIRING DIAGRAM CABLE SUPPLIED BY SpUTHIAND. ELECTRICAL CONTRACTOR <br /> DRAWING <br /> EF4 scALc NONE 4 CABLE DETAILS FE-2 <br /> NONE <br /> � POS GAS CONTROLLER DIAGRAM <br /> - - EF4 SCALE NONE / <br /> _ — <br /> i <br />