BILLING 2004 - 2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4501
>
2300 - Underground Storage Tank Program
>
PR0231233
>
BILLING 2004 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 11:34:31 AM
Creation date
11/6/2018 10:26:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2004 - 2009
RECORD_ID
PR0231233
PE
2361
FACILITY_ID
FA0002479
FACILITY_NAME
7-ELEVEN INC #17334
STREET_NUMBER
4501
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11017004
CURRENT_STATUS
01
SITE_LOCATION
4501 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PERSHING\4501\PR0231233\BILLING 2004 - 2009.PDF
QuestysFileName
BILLING 2004 - 2009
QuestysRecordDate
8/25/2016 5:38:51 PM
QuestysRecordID
3175459
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FEB-03-2007 00:54 7-ELEVEN INC NW DIU. 503 977 7711 P.03iO4 <br /> UNDERGROe—ND STORAGE TANK MOi erORING PLAN <br /> For use by Unidocs Member Agencies or where approved by your Local Jurisdiction <br /> Authority Cited- Title 23 CCR, Sections 2632(d)(1), 2634(d)(2), and 2641(h) <br /> TYPE OF ACTION ❑ 1.NEW PLAN ® 7,CHANGE OF INFORMATION MCI. <br /> PLAN TYPE 0 MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. Mut_ <br /> (Check one item only) ❑ THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) _ <br /> FACILITY NAME 7-Eleven#17:3.34 Mm. <br /> FACILITY SITE ADDRESS 4501 N. Pershing M0"' CITY Stockton Mps. <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> State law requires that testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak dotectors,etc.)be performed in M06. <br /> accordance with the equipment manufacturers'instructions,or annually,whichcvor is more frequent, Such work must be performed by qualified personnel. <br /> MONITORING EQUIPMENT IS SERVICED 0 1.ANNUALLY ❑ 99.OTHER(Specify): W1 <br /> III. MONITORING LOCATIONS <br /> 'Ibis monitoring plan must inchtde a Site Plan showing the general tank and piping layouts and the locations where monitoring is performed(i.e.,location of each sensor, <br /> line Irak detector,monitoring system contml panel,etc.). If you already have a diagram(e.g.,current UST Monitoring Site Plan from a Monitoring System Certification <br /> form,Hazardous Materials Business Plan map,etc.)which shows all required information,include it with this plan. <br /> IV. TANK MONITORING <br /> MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S);(Check all that apply) M10_ <br /> ® 1.CONTINUOUS ELECTRONIC MONITORING OF TANK ANNULAR n(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) <br /> SECONDARY CONTAINMENT IS: X a.DRY 0--1;, R�+�•' LLP11 ❑ c.UNDER PRESSURE ❑ d.UNDER VACUUM M°. <br /> PANEL MANUFACTURER; y@ed@IRoot M12, MODEL#: TL5350 M1a, <br /> LEAK SENSOR MANUFACTURER: Vee@ t M14. MODELgsy 794390.420 Mia, <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SNGj1WALLj6BKfSj <br /> PANEL MANUFACTURER: M16MODEL#: M17. <br /> IN-TANK PROBE MANUFACTURER MI6, MODEL 4(S): M19. <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILYINIGHTLY ❑ c.WEEKLY Mx. <br /> ❑ d.MONTHLY ❑ c.OTHER(Specify): ear. <br /> PROGRAMMED TESTS: ❑ a.0.1 g.p.h. ❑ b.0.2 g.p.h. ❑ c.OTHER(Specify): Ma. Mal <br /> © 3.INVENTORY RECONCILIATION [] a.MANUAL PER 23 CCR§2646 ❑ b.STATISTICAL PER 23 CCR§2646.1 M=° <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)PER 23 CCR§264$ <br /> TESTING PERIOD- ❑ a.36 HOURS ❑ b.60 HOURS Ms. <br /> ❑ <br /> S.INTEGRITY TESTING PER 23 CCR§2643.1 <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY [3 c.OTHER(Specify): Ms. Mr. , <br /> ❑ 6.VISUALMONITORING DONE: ❑ a,DAILY ❑ b.WEEKLY prequan etency appm4 <br /> ❑ 99.OTHER(Specify): M78 <br /> V. PIPE MONITORING <br /> MON]TORING IS PERFORMED USING THE FOLLOWING METHOD(S)(Check all that apply) Mo. <br /> ® 1.CONTINUOUS ELECTRONIC MONITORING Of PIPING SUMP(SYTRENCH(ES)AND OTHER SECONDARY CONTAINMENT <br /> SECONDARY CONTAINMENT IS: 0 a.DRY ❑ b.LIQUID FILLED ❑ c.UNDER PRESSURE ❑ d.UNDER VACUUM wi <br /> PANEL MANUFACTURER:VeederRoot Mia• MODEL#: TL5350 Mal_ <br /> LEAK SENSOR MANUFACTURER: VeederROot Mao. MODEL#(S): 794380-852 ave_ <br /> WILL A PIPING LEAK ALARM TRIGGER AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN? 0 a.YES ❑ b.NO Mi6. <br /> WILL FAILURF/DISCONNECTION OF THE MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? 0 a.YES ❑ b.NO Mli <br /> 0 2.MECHANICAL LINE LEAK DETECTOR (MLLD) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED <br /> MLLD MAN UFACTURER(s):V200TIOSS & RedJaCket M'6' MODEL#(s): LD2,000& FX1V Mf°. <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p,h.LEAK TESTS <br /> ELLD MANUFACTURER: "' MODEL#; M41. <br /> PROGRAMMED LINE INTEGRITY TESTS: ❑ a.MINIMUM MONTHLY 0.2 g,p.h. ❑ b.MINIMUM ANNUAL 0,1 g.p.h. ANi. <br /> WILL ELLD DETEL'I'ION OF A PIPING LEAK TRIGGER AUTOMATIC PUMP SHUTDOWN? ❑ a.YES ❑ b.NO M41_ <br /> WILL ELLD FAILUREMISCONNECTION TRIGGER AUTOMATIC PUMP SHUTDOWN? ❑ e.YES ❑ it,NO Mea. <br /> 0 4,INTEGRITY TESTING <br /> TEST FREQUENCY: 0 a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ a OTHER(Specify) sws. mop. <br /> ❑ S.VISUALMONRORINGDONE; ❑ a.DAILY ❑ b.WEEKLY- ❑ 0.MIN.MONTHLY&EACH TIME SYSTEM OPERATED" Mor, <br /> •Requ'vn eaeaq,gpre.d ••All4wen tar 4faeiroriea erugyeu{ed emerae°eya�e�PT�4a Only per HSC 4Z33913(b)(l) <br /> ❑ 6.PIPING IS SUCTION PIPING MEETING ALL REQUIREMENTS FOR EXEMPTION FROM MONITORING PER 23 CCR§2636(x)(3) <br /> ❑ 7.NO PRODUCT OR REMOTE FILL PIPING IS CONNECTED TO THE UST(s) <br /> ❑ 99,OTHER(Specify) Mor. <br /> UN-032A-1/3 www.unk oCLorg Rev.10/14/03 <br />