Laserfiche WebLink
QIFIED PROGRAM CONSOLIDATED Ff I <br /> UNDERGROUND STORAGE TANK F. <br /> MONITORING PLAN - (Pae 1 of 2) <br /> TYPE OF ACTION ❑ 1.NEW PLAN ® 2.CHANGE OF INFORMATION 490-1. <br /> PLAN TYPE ® L MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490-2. <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> FACILITY ID#(Agency Use Only) I. FACILITY INFORMATION 1 <br /> BUSINESS NAME(Same as Facility Name or DBA) <br /> 7-Eleven # 17334 3 <br /> BUSINESS SITE ADDRESS 4501 N. Pershing 103. CITY <br /> Stockton u4. <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> by the equipment manufacturers' instructions,or annually,whichever is more frequent.Such work must be performed by qualified personnel.1?3 CCR 52632 2634,2638.3641 <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY --- <br /> ❑ 99.OTHER(Specify): 4%3 <br /> 4911-3b. <br /> III. MONITORING LOCATIONS <br /> ❑ I.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ® 2.SITE PLOT PLAN/MAP PREVIOUSLY SUB ITTED 123CCR§2632,26341 4%4 <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) 'Check(B <br /> L CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACES)OR SECONDARY CONTAINMENT VAULT(S) --5- <br /> WITH AUDIBLE AND VISUAL ALARMS.123 CCR§2632.M341 <br /> SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 49x5. <br /> PANEL MANUFACTURER: Veeder-Root 4947. MODEL#: TLS-350 690-6' <br /> LEAK SENSOR MANUFACTURER: Veeder-Root 490"9. MODEL#(S): 794390-420 49410' <br /> .............._____............ _ _____.._............._.. ....._'_ <br /> E0:3 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(Sl.123 ccR§z6a31 49411. <br /> PANEL MANUFACTURER: 490.12. MODE-L#: 49 13. <br /> IN-TANK PROBE MANUFACTURER: 49414. MODEL#(S): 49x15. <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 49x16. <br /> Eld.MONTHLY 11e.OTHER(Specify): 49417. <br /> _._.......___PROGRAMMED.TESTS__..___- a.0. g.p.h. [ _b:.0.2.g.p.h _,.____.._...❑ c.OTHER . ........... <br /> ❑ 3.MONTHLY STATISTICAL PIVENTORY RECONCILIATION 123 ccR§2646.11 490.20. <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MIG)Iz-CCR§z64s] TESTING PERIOD ❑ a. ----H---0- 0RS ❑ 6 60 HOURS 49 22. . <br /> 5.TANK INTEGRITY TES77NG PER[z3 ccR§z6a3.11 _-.. -_....49423. <br /> TEST FREQUENCY: a.ANNUALLY 4r)24. <br /> Q ❑ ❑ b.BIENNIALLY ® c.OTHER(Specify) SB989 every 36 months 441-25. <br /> ® 99.OTHER(Specify): Overfill protection-Flapper 490-M <br /> 44'7. <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) �h"" <br /> ® L CONTINUOUS MONITORING OF PIPF/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 4%28- <br /> 123 CCR SECONDARY CONTAINMENT IS: ® DRY b.LIQUID FILLED c.PRESSURIZED 490x9. <br /> §26361 z. ❑ Q ❑ ❑ d.UNDER VACUUM <br /> PANEL MANUFACTURER:Veeder-Root 490.3°. MODEL#: TLS-350 49431. <br /> LEAK SENSOR MANUFACTURER: Veeder-Root 49432. MODEL#(s): 794380-352 49°33' <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ® a.YES ❑ b.NO 490.34. <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 49435. <br /> 2.MECHANICAL LINE KD (MELD)THAT ROUTINELY PERFORMS 3 0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTSOFF 490.36. <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.123 CCR§26361 <br /> MLLD MANUFACTURER(S):Vaporle33 & Red Jacket 49437. MODEL#(s): LD2000 & FX1 V 49438. <br /> ❑ 3 ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.123 rat§26361 49439. <br /> ELLD MANUFACTURER(S): 490"40' MODEL#(S): 49441. <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 490-42. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 490-43- <br /> FI I <br /> 90-43.ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. [I [Ia.YES b.NO 494a4. <br /> ......... <br /> ® 4.PIPE INTEGRITY TESTING. ... .... _------------------------------__.-_ <br /> 49445. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ® C.OTHER(Specify) SB989 every 36 mo. 4 '46. <br /> ............ <br /> ❑ 5.VISUALPIPE MONITORING ___.._.__.... .............. ...__.__ ...._ 490-Os. <br /> FREQUENCY: ❑ a.DAILY ❑ b.WEEKLY ❑ c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED- 490'49 <br /> 'Albwed fo ndorinl of unWriN.emergercY gererator fuelpp ng only�er HSC§3..813(6X3) <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA.[Xi CCR§2636(.X3)1 49430 <br /> .. .. ........... ------- <br /> -_ -.... ......... .......... _..__..____.... .___.._.. <br /> ❑ 7 NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM 49x51. <br /> ..............__ __ <br /> ❑ 99.OTHER(Specify) -_ __ ..._....___. ....._ <br /> d9US2. <br /> 49433. <br /> UPCF UST-D(122007)-V4 Svtrw.uoidoc9.org <br />