My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PESCADERO
>
1535
>
2300 - Underground Storage Tank Program
>
PR0232495
>
COMPLIANCE INFO 2012 - 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 2:11:02 PM
Creation date
11/6/2018 10:35:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2014
RECORD_ID
PR0232495
PE
2361
FACILITY_ID
FA0003854
FACILITY_NAME
YRC INC
STREET_NUMBER
1535
Direction
E
STREET_NAME
PESCADERO
STREET_TYPE
Ave
City
Tracy
Zip
95304
APN
21306026
CURRENT_STATUS
01
SITE_LOCATION
1535 E Pescadero Ave
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PESCADERO\1535\PR0232495\COMPLIANCE INFO 2012 - 2014 .PDF
QuestysFileName
COMPLIANCE INFO 2012 - 2014
QuestysRecordDate
12/8/2016 9:18:09 PM
QuestysRecordID
3274874
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
153
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
` SAN JOAQUIN COUNTY ~ <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.orG/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Faciftme YRC Inc/ Yellow Freight Fadlity 1535 East Pescadero Ave, Tracy oats°n Mar 8, 2013 <br /> Name. 9 Address: <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Safety Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 vidation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (MI) <br /> 703 CCR 2643(4) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (MI) <br /> Other Vlolatlons <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> UST Inspection: Routine and Annual Monitoring System Certification <br /> 113. Failed to inform EHD of change of designated operator within 30 days. An Owner Statement of <br /> Designated UST Operator dated 05/24/12 lists Steve Coulter and Jarrod Cooke as facility's Designated <br /> Operators (DOs). Another Owner Statement dated 02/19/13 lists Jarrod Cooke, George Zoumalan and <br /> Randall Kirby as facility's current DOs. Alex Fast has been performing six monthly visual inspection <br /> reports from June 2012 to December 2012 but he is not listed as facilty's authorized DOs. No <br /> notification were not provided to the EHD within 30 days of the change. EHD was not sent a copy of the <br /> Owner Statement dated 05/2012 and 02/2013. Any changes shall be reported to the EHD with 30 days. <br /> Submit notification to the EHD identifying all the designated operators for this facility when facility's is <br /> adding an individual prior to allow the individual performing the monthly visual inspection reports. <br /> 204. No documentation of alarms for L6 T-2 annular space were documented. The designated operator <br /> failed to document all the alarms from the attached alarm history on the August 2012 designated <br /> operator monthly inspection report and failed to check that they were responded to appropriately. The <br /> missing alarms include: low liquid alarms on August 20, 2012. During the monthly inspection, the <br /> designated operator shall review the alarm history for the previous month, check that each alarm was <br /> documented and responded to appropriately, and attach a copy of the alarm history with documentation <br /> taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports. Submit a <br /> statement that L6 alarm will be documented along with any action taken in response to the low liquid <br /> alarm. <br /> ALL EMD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br /> Inepelor /' lyse, y' T <br /> I <br /> EHD 23-02 Rev 04/19/12 Page 3 UST IN ECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.