Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PESCADERO
>
1535
>
2300 - Underground Storage Tank Program
>
PR0232495
>
COMPLIANCE INFO 2012 - 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 2:11:02 PM
Creation date
11/6/2018 10:35:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2014
RECORD_ID
PR0232495
PE
2361
FACILITY_ID
FA0003854
FACILITY_NAME
YRC INC
STREET_NUMBER
1535
Direction
E
STREET_NAME
PESCADERO
STREET_TYPE
Ave
City
Tracy
Zip
95304
APN
21306026
CURRENT_STATUS
01
SITE_LOCATION
1535 E Pescadero Ave
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PESCADERO\1535\PR0232495\COMPLIANCE INFO 2012 - 2014 .PDF
QuestysFileName
COMPLIANCE INFO 2012 - 2014
QuestysRecordDate
12/8/2016 9:18:09 PM
QuestysRecordID
3274874
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
153
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root RID Liq -"ttp://www.nwgide.org/evals/veeder—root—r.hW <br /> Issue Date:November 22,1995 <br /> Revision Date:Jure 10,2013 <br /> Veeder-Root <br /> ILS-350,TLS-3000,3001,300PC,350,35oPC,350R,350RPC,TLS-450 Series, Red Jacket ProMax and ProPlus <br /> with Solid-State Pan/Sump Sensor 794380-321,351, <br /> Piping Sump Sensor 794380-208, 209, <br /> Micro Sensor 794380-340 <br /> INTERSTITIAL DETECTOR (LIQUID-PHASE) <br /> Detector: <br /> Output type: qualitative <br /> Sampling frequency: continuous <br /> Operating principle: float/reed switch(794380-208,209),optical(794380-321,340,351) <br /> Test Results: <br /> unleaded Dasoline diesel* water used oil <br /> Solid-State Pan/Sump Sensor 794380-321, <br /> 351 <br /> Minimum product thickness(an) 2.60 2.50 2.60 N/D**** <br /> Precision(cm) 0.010 0.010 0.010 N/D**** <br /> Detection time(sec) <1 <1 <1 N/D**** <br /> Piping Sump Sensor 794380-208**,209 <br /> Minimum product level(am) 3.51 3.40 3.03 3.76 <br /> Precision(an) 0.011 0.011 0.011 .036 <br /> Detection time(sec) <1 <1 <1 <1 <br /> Micro Sensor 794380-340*** <br /> Minimum product thickness(an) 0.51 0.46 0.48 N/D**** <br /> Precision(cm) 0.011 0.007 0.007 N/D**** <br /> Detection time(sec) <1 <1 <1 N/D**** <br /> *Evaluations determined these sensors'responses to the liquids shown above. Biodiesel blends 136-B20 meeting ASTM D7467 and biodiesel <br /> 8100 meeting ASTM D6751 would also produce an alarm if the sensor threshold is exceeded. Responses to these fuels were not <br /> determined,but would be expected to be very similar to the diesel responses. <br /> **This sensor is identified as an interstitial sensor,but will function properly in other containment areas such as containment sumps, <br /> contained risers and other contained enclosures. This sensor must be installed at the lowest point of the containment enclosure to insure <br /> early detection of liquids. Results stated for used oil applicable to this sensor only. <br /> *** Micro Sensor 794380-340 is not supported by TLS 450 series console. <br /> ****See Glossary <br /> Comments: <br /> Sensors are reusable. <br /> 208 and 209 sensors are also compatible with 300 series. <br /> Comparison of TLS450 with TLS-350 series console showed comparable results when evaluated with representative sensors. <br /> Veeder-Root Evaluator: Ken Wilcox Associates <br /> 125 Powder Forest Dr. Tel: (816)443-2494 <br /> Simsbury,CT 06070-2003 Dates of Evaluations: 10/20/94,05/22/02,03/03/08,04/15/11 <br /> Tel: (860)651-2700 <br /> E-mail:dhalla@veedercDm <br /> URL:www.veedercDm/dynamic/index.cfim <br /> 4004— <br /> I Home I Vendors:A -_F I Vendors:G- M I Vendors: N- S I Vendors:T-2 1 Method Index I Glossary I <br /> Appearance on this list is not to be construed as on eMorsement by any regulatory agency nor is it any guarantee of the Ioer/orttunce of the method or equiprreM. <br /> Equipment should be installed and operated in accordaree with all applicable laws and regulations. For full details,please refer to our ex"nvieel'DISCLAIMER"page. <br />
The URL can be used to link to this page
Your browser does not support the video tag.