COMPLIANCE INFO 1998-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PINE
>
1126
>
2300 - Underground Storage Tank Program
>
PR0231364
>
COMPLIANCE INFO 1998-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:17 AM
Creation date
11/6/2018 10:51:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2003
RECORD_ID
PR0231364
PE
2361
FACILITY_ID
FA0003771
FACILITY_NAME
E F KLUDT & SONS INC
STREET_NUMBER
1126
Direction
E
STREET_NAME
PINE
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04906022
CURRENT_STATUS
01
SITE_LOCATION
1126 E PINE ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PINE\1126\PR0231364\COMPLIANCE INFO 1998-2003.PDF
QuestysFileName
COMPLIANCE INFO 1998-2003
QuestysRecordDate
9/7/2017 9:00:20 PM
QuestysRecordID
3628601
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
218
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Flexible Boot Maillival environ <br /> 1.4 Chemical Compatibility Part No. Size Application <br /> All seals are made of specially formulated Buna-N Rubber compound FEB-3050 112" Standard use <br /> which has been independently tested to insure its compatibility with a FEB-3075(4.25"O.D.) 314" Standard use <br /> wide assortment of chemicals measuring its swell features under FEB-3075A(3"O.D.) 314" Congested areas <br /> exposure as well as degradation characteristics.These tests included FEB-3100 1" Standard use <br /> measuring the material's retention of properties as well as the physical <br /> characteristics of the seal after exposure. <br /> WARNING: Keep all fiberglass cleaning solvents away from 2.2 Pipe Entries <br /> boots.These types of solvents could cause severe damage. There are eight sizes of pipe entry <br /> boots to accommodate various types of <br /> piping. These entry boots may be <br /> 1.5 Angled Entries installed in either the sidewall of a <br /> dispenser sump or in the bottom of a <br /> Flexible entry boots are flexible enough dispenser pan. <br /> to permit angled pipe or conduit entries <br /> (on two axis) into the sidewall of a <br /> containment chamber. This seal is "{ <br /> also capable of multi-directional pipe <br /> alignment either up and down or side <br /> to side. This vital feature also allows Part No. Size Application <br /> accommodation of pipe entry holes FEB-3150 1-112" Flex and Rigid Pipe <br /> which are installed slightly off exact FEB-5150 1-112" Flex and Rigid Pipe <br /> alignment in the chamber wall. This FEB-6150 1-112" Flex and Rigid Pipe <br /> movement will prevent the chamber wall from putting undue stress FEB-6200 2" Flex and Riclict Pipe <br /> on the pipe coupling/fitting joint and the entry boat as well. For flexible <br /> piping applications within dispenser sumps, the stresses on pipe FEB 6300 3" Flex and Rigid Pipe <br /> fittings below the product dispenser's inlets are minimized by the FEB-7390 3.9" Ri id Pi e&Containment&Flex <br /> boot's alignment flexibility. FEB-7400 4" Rt id Pipe <br /> Pipe and conduit entering the containment chambers may not be FEB-8600 6" Rigid Pipe <br /> perpendicular with the wall of the chamber. Angled entries are <br /> generally a result of directional plumbing restrictions on the inside of 2,3 Duct Entry Boots <br /> the containment chamber due to space limitations.All flexible entry <br /> boots permit angled entries up to a 15 degree angle off the center line There are two sizes of duct entry boots =' <br /> in any direction without breaking a seal or putting undue stress on the to accommodate both flexible and rigid <br /> pipe conduit or entry seal. ducting. Ducting pipe is typically used <br /> when removability of the flexible pipe is <br /> r <br /> WARNING: Angles greater than 15 degrees off center could desired after installation. These entry <br /> boots may be installed only in the <br /> possibly cause the rubber boot to tear due to prolonged sidewall of a dispenser sump. These <br /> stress, boots typically require the use of split <br /> reducer donuts to seal the boot when <br /> reducing down from ducting to the <br /> 2. ENTRY BOOT APPLICATIONS primary piping. <br /> There are a number of different sizes i <br /> and types of flexible entry boots Part No. Size Application <br /> designed to meet all GeoFlex51 system `• FEB-6350 3" Standard use <br /> applications. The following types of FEB-7450 4" Standard use <br /> flexible entry boats and seals available <br /> are described as follows: <br /> 3. INSTALLATION INSTRUCTIONS <br /> i <br /> For proper and warranted installation of <br /> 2.1 Conduit Entries flexible entry boots, these instructions <br /> There are four sizes of conduit entry must be followed. Prior to installing the <br /> boots made to-accommodate 111", 1 rubber entry boots,make sure the exact <br /> 3/4",1", conduit.These entry boots may location has been properly calculated. <br /> be installed in either the sidewall of a sump access boots may be used to <br /> dispenser sump or in the bottom of a permanently seal any miscalculations. <br /> r <br /> dispenser par, <br /> M <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.