My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PINE
>
1126
>
2300 - Underground Storage Tank Program
>
PR0231364
>
COMPLIANCE INFO 1998-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:17 AM
Creation date
11/6/2018 10:51:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2003
RECORD_ID
PR0231364
PE
2361
FACILITY_ID
FA0003771
FACILITY_NAME
E F KLUDT & SONS INC
STREET_NUMBER
1126
Direction
E
STREET_NAME
PINE
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04906022
CURRENT_STATUS
01
SITE_LOCATION
1126 E PINE ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PINE\1126\PR0231364\COMPLIANCE INFO 1998-2003.PDF
QuestysFileName
COMPLIANCE INFO 1998-2003
QuestysRecordDate
9/7/2017 9:00:20 PM
QuestysRecordID
3628601
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
218
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�_7� LO N s <br /> KLUDT,IRE:ORLMERPO BOA: 166LODI,CA 95 � <br /> FORMAL NOTIFICATION TO OWNERS <br /> TO IMPLEMENT ENHANCED LEAK DETECTION TESTING <br /> This is a formal notification that your Underground storage lank(UST)system is subject to Enhanced <br /> Leak Detection(ELD)testing,based on infonnation in the State Water Resources Control Board's <br /> (SWRCB's)Geographical Information System(GIS)Wrapping database("Geotracker").Our <br /> information indicates that your UST system is located within 1000 feet of a public drinking water well. <br /> Part A of this letter discusses facility and well data related to Geotracker. Part B explains the ELD <br /> requirements for UST systems with a single-walled component. Part C explains the ELD requirements <br /> for UST systems with secondary containment. Part D explains the process for requesting <br /> reconsideration of this notification. <br /> PART A. UST FACILITY AND WELL DATA RELATED TO GEOTRACKER <br /> Local permitting agencies submitted UST facility data to the SWRCB for entry into Geotracker. UST <br /> facility information is available on http://geotTacker.swrcb.ca.gov,the Geotracker web site. Enclosure <br /> I is a street map showing the location of your facility,according to Geotracker <br /> The Department of Health Services and local water districts provided information on locations of <br /> public drinking water wells and their locations into Geotracker.Due to recent security concerns,well <br /> location information is not available to the public.Enclosure 2 provides the Facility ID and PIN <br /> numbers for the UST system,the name of the water purveyor(owner of the water system),and the <br /> name and telephone number for their contact person. <br /> We have attempted to improve the accuracy of the infonnation in the Geotracker database. However, <br /> the database may still require updating to make it current and complete. As described in Part D below, <br /> if you believe Geotracker's information regarding your UST system is inaccurate,or the water <br /> purveyor can confirm that nearby public drinking water well data are inaccurate,you may request <br /> reconsideration. <br /> To verify well information,you will need to contact the water purveyor. <br /> PART B. UST SYSTEMS WITH A SINGLE-WALLED COMPONENT <br /> For UST systems with a single-wailed component,ELD testing is required once every three years <br /> (Health Saf.Code,§25292.4 and Cal.Code of Regs.,tit.23,§§2640 and 2644.1).Also,please refer <br /> to Enclosure 3,Local Guidance Letter 161-1. Triennial ELD testing is required for UST systems with <br /> one or more of the following single-walled components: <br /> *single-walled tank, <br /> *single-walled pressurized piping, <br /> *single-walled conventional suction piping. <br /> *dispensers without under-dispenser containnent,and <br /> * turbines without secondary containment. <br /> Vent or tank riser piping,vapor recover},piping,and"safe"or"European"suction piping are not <br /> considered single-walled components if the),meet the applicable criteria in the regulations[Cal.Code <br /> of Regs.,tit. 23,§2636,subd. (a)J. <br />
The URL can be used to link to this page
Your browser does not support the video tag.