My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010 REPAIR
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2010 REPAIR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 4:17:01 PM
Creation date
11/6/2018 12:09:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 REPAIR
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\S\SAN JOAQUIN\345\PR0231867\REPAIR PLAN 2010.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
245
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB.January 2002 Page 2 of 5 <br /> 4.TANK ANNULAR TESTING <br /> Test Method Developed by ® Tank Manufacturer ❑ Industry Standard ❑ Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used ❑ Pressure ® vacuum ❑ Hydrostatic <br /> ❑ Other(specify) <br /> Test Equipment Used:4"Liquid Gauge Equipment Resolution: .2 <br /> Tank#UE042V001 Tank# Tank# Tank# <br /> is Tank Exempt From Testing?(t) ❑ Yes 0 No Cl Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Tank Capacity: 25,018 <br /> Tank Material: Steel/Clad <br /> Tank Manufacturer: Modem Weld <br /> Product Stored, Diesel <br /> Wait Time between applying 15 min <br /> pressure/vacuum/water and starting <br /> test: <br /> Test Start Time: 10.40 am <br /> Initial Reading(Ri): -10" ISG <br /> Test End Time: 11:40 am <br /> Final Reading(Rt): -1,0"HG <br /> Test Duration: 1 hour <br /> Change in Reading(Rf-Ri): 0 <br /> Pass/Fail Threshold or Criteria: 0 <br /> Test Result ® Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> Was Sensor Removed for Testing? ® Yea ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yrs ❑ No ❑ NA ❑ Ycs ❑ No ❑ NA <br /> Was Sensor properly replaced and <br /> verified functional after testing? ❑ Ycs 0 No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Ycs ❑ No ❑ NA ❑ Yes ❑ No C1 NA <br /> Comments include any information on repairs made prior to testing,and recommended follow-up for failed tests <br /> The sensor was reinstalled to the lowest point,but not tested. <br /> 11)Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary containment,such as <br /> sysrtems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment resting. ;California Code of <br /> Regulations,Title 23,Section 2637(a)(6)l <br />
The URL can be used to link to this page
Your browser does not support the video tag.