My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010 REPAIR
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2010 REPAIR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 4:17:01 PM
Creation date
11/6/2018 12:09:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 REPAIR
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\S\SAN JOAQUIN\345\PR0231867\REPAIR PLAN 2010.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
245
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 5 of 5 <br /> 8.FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed by ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used ❑ Pressure ❑ Vacuum N Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used:Incon TS-STS Equipment Resolution: .0006 <br /> Fill Sump#Middle Fill Sump# Fill Sump# Fill Sump# <br /> UE042UO01 UE042U001 <br /> Sump Diameter: 38" 38" <br /> Sump Depth: 41" 40.5" <br /> Height from Tank Top to Top of NIA 10" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 14" 8" <br /> Electrical Penetration: <br /> Condition of sum prior to testing: Good Good <br /> Portion of Sump Tested: 2"Above Collar <br /> Sumv Material: Fiber lass Fiberglass <br /> Wait time between applying 15 Min <br /> pressure/vacuum/water and starting <br /> test: <br /> Test Start Time.. 10:20 AM 10:36 AM <br /> Initial Reading i : 2.9936 2.9938 <br /> Test End Time: 10:35 AM 10:51 AM <br /> Final Reading 2.9937 2.9935 <br /> Test Duration: 15 Min 15 Min <br /> Chanize in Reading f-Ri : .0001 .0003 <br /> Pass/Fail Threshold or Criteria: .002 .002 <br /> Test Result: ® Pass ❑ Fail ❑ Pass ® FaiI ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> Is there a sensor in the sump? ® Yes ❑ No ® Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Does the sensor alarm when either ❑ Yes ® No ❑ NA ❑ Yes ® No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br /> roduct or water is detected? <br /> Was sensor removed for testing? ® Yes ❑ No ❑ NA ❑ Yes ® No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br /> Was sensor properly replaced and ❑ NA ❑ Yes ❑ No ❑ NA [IYes ❑ No ❑ NA <br /> verified functional after testing? Elly:111 <br /> ® No ❑ NA 11P Yes ® No <br /> Comments include any information on re airs made prior to testing,and recommended follow-up for failed tests <br /> The Middle Sump sensor were reinstalled to the lowest point,but not tested. <br /> The Fill Sump is a visual failure due to the Vent Secondary cracked test boot.Did not put any test water into the fill sump. <br />
The URL can be used to link to this page
Your browser does not support the video tag.