My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
401
>
2300 - Underground Storage Tank Program
>
PR0501586
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/6/2020 1:02:31 PM
Creation date
11/6/2018 12:13:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0501586
PE
2381
FACILITY_ID
FA0005154
FACILITY_NAME
FEDERAL BUILDING/US POST OFC
STREET_NUMBER
401
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13915005
CURRENT_STATUS
02
SITE_LOCATION
401 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SAN JOAQUIN\401\PR0501586\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
9/26/2017 7:25:26 PM
QuestysRecordID
3648491
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD nF e e <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B e <br /> MARK ONLY 1 NEW PERMIT <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. ` D- <br /> ❑ <br /> ONE ITEM 2 INTERIM PE❑ 3 RENEWAL PERMIT O 5 CHANGE OF INFORMATION <br /> RMIT ❑❑ 4 AMENDED PERMIT 7 PERMANENTLY CLOSED ON SITE <br /> 6 TEMPORARY TANK CLOSURE <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: �'O /❑ <br /> B TANK REMOVED <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D. <br /> a <br /> C. DATE INSTALLED(MO/DAYIYEAR) B. MANUFACTURED BY: <br /> IIJANKCONTENTSFA-1 IS MARKED,COMPLETE ITEMC. O• TANK CAPACITY IN GALLONS: 5 QOO <br /> A. ❑ 1 MOTOR VEHICLE FUEL <br /> 04c B. <br /> RC1 2 PETROLEUM C. ❑ 1a REGULAR 3 DIESEL 6 AVIATION GAS <br /> ❑ 1 PRODD eD EMPTY UCT UNLEADE ❑ <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ lb PREMI D 5 ETFUELL ❑ <br /> ❑ 2 WASTE ❑ 7 METHANOL <br /> D. IF(p.7)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED ❑ 2 LEADED <br /> ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C,AND ALL THAT APPLIES IN BOX D AND E C A'S. <br /> A. TYPE OF ❑ 7 DOUBLE WALL <br /> SYSTEM �7�r�" ❑ 3 SINGLE WITH EXTERIOR LINER <br /> �^ 2 SINGLE WALL ❑ q SECONDARYARY CONTAINMENT (VAULTEOTAN ❑ 95 UNKNOWN <br /> 1 BARE ❑ OTHER <br /> STEEL <br /> B. TANK ❑ 2 STAINLESS STEEL <br /> MATERIAL ❑ 5 CONCRETE ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> (PrimaryTank) <br /> ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM <br /> ❑ 9 BRONZE El 100% METHANOL COMPATIBLE W/FRP <br /> El 10 GALVANIZED STEEL ❑ 95 UNKNOWN <br /> ❑ 1 RUBBER LINED ❑ OTHER <br /> C.INTERIOR ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING <br /> LINING ❑ 5 GLASS LINING ❑ 4 PHENOLIC LINING <br /> 6 UNLINED ❑ 95 UNKNOWN <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES <br /> ❑ OTHER <br /> YES_ NO— <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING <br /> PROTECTION ❑ 5 CATHODIC PgOTECTION_�<91 NONE ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> ❑ 85 UNKNOWN <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) ❑ 99 OTHER <br /> IV.PIPING INFORMATION CIRCLE A IFASOVEGROUNDOR U IF UNDERGROUND,BOTH OVERFILL TK)N EQUIPMENT INSTALLED F APPLICAB EYEAR) <br /> A. SYSTEM TYPE 7 SUCTION A U 2PRESSURE <br /> 09 A U 3 GRAVITY <br /> B. CONSTRUCTION A U 99 OTHER <br /> A 1 SINGLE WALL A U 2 DOUBLE WALL {° <br /> U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE 4 FIBERGLASS PIPE <br /> PROTECTION p U 9 GALVANIZED STEEL A U 10 CATHODCPROTECT ON 7 STEEL W/COATING A U 8 100% METHANOL COMPATISLEW/FRP <br /> A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ J <br /> V.TANK LEAK DETECTION MONRORING 9B OTHER Q - <br /> ❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING O 5 GROUND WATER MONITORING <br /> ❑ 6 TAN(TESTING ❑ 7 INTERSTITIAL MONITORING 91 NONE ❑ 95 UNKNOWN <br /> El 99 OTHER <br /> VL TANK CLOSURE INFORMATION <br /> Lf <br /> ESTIMATE D E LAST.USED(MO/DAY/YR) 2.ESTIMATED QUANT_ <br /> YfY OF <br /> SUBSTANCE REMAINING 3.WAS TANK FILLEDWITH <br /> GALLONS INERT MATERIAL? YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME <br /> (PRINTED A SIGNATURE) <br /> DATE <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMCOMPOSED OFTHE FOUR NUMBERS BELOW D Try <br /> COUNTY N JURISDICTION aY V O 5" <br /> STATE I.D.# FACILITY TANK# <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE <br /> PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORM A.UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FORM B (12-91) <br /> FILE THIS FORM WITH AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> +� as� 9s FORD( WBAS <br />
The URL can be used to link to this page
Your browser does not support the video tag.