My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SANGUINETTI
>
0
>
2300 - Underground Storage Tank Program
>
PR0504932
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2020 11:04:12 PM
Creation date
11/6/2018 12:26:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0504932
PE
2381
FACILITY_ID
FA0006420
FACILITY_NAME
OAKMORE MEADOWS
STREET_NUMBER
0
STREET_NAME
SANGUINETTI
STREET_TYPE
LN
City
STOCKTON
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
SANGUINETTI LN
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SANGUINETTI\0\PR0504932\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
10/17/2017 6:39:06 PM
QuestysRecordID
3685606
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APRICAIIM-FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYS <br /> MARK ONLY 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE 5 K'ii1>^�g ❑ 7 PERMANENTLY CLOSED ONSITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORA . –, ❑ 8 TANK REMOVED /'5, <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: vlh�A <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS– SPECIFY IF UNKNOWNIff <br /> A. OWNER'S TANK I.D.• ©/ B. MANUFACTUE03Y; u ti <br /> Ii I <br /> p r n <br /> C. DATE INSTALLED(MO/DAY/YEAR) �i�o�✓17 D. TANK CAPAC'?'N T :731E- /' D J ...) <br /> ILTANKCONTENTS IFA-11S MARKED,COMPLETE ITEM C. <br /> A ❑ 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. c. ❑ �U>�N:3TM 3 DIESEL ❑ 8 AVIATION GAS <br /> ❑ 2 PETROLEUM 80 EMPTY ❑ 1 PRODUCT ❑ M7;Jplly —� 4 GASAHOL ❑ 7 METHANOL <br /> ❑ 3 CHEMICALPRODUCT 4 UNKNOWN ❑ 2 WASTE ❑ 2 �_I 5 JETFUEL <br /> '❑ 99 OTHER (DESCRIBE IN ITEM D: BELOYJI <br /> D. IF(A.1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED <br /> C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B.AND C,AND ALL THAT APPLIES b 3OXDAOs <br /> A. TYPE OF ❑ 1 BLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ g(UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTEOTANIQ 16 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS A STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM { -00% METHANOL COMPATIBLE W/FRP <br /> (PrimaryTank) ❑ g BRONZE ❑ 10 GALVANIZED STEEL ;�3 �_UNKNOWN R OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING 4 PHENOLIC LINING <br /> C.INT <br /> ERIOR <br /> NIGR ❑ 5 GLASS LINING ❑ 6 UNLINED [2-99–UNKNOWN ❑ 90 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ NO— <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODICPROTECTION ❑ 91 NONE UNKNOWN CI 20 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENrCH EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGROUNDOR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A 5 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION 85 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING MONROflING A 99 OTHER <br /> ❑ <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> ❑ 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING1 NONE 85 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF 3.WAS <br /> TANK FILLED WITH <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? YES ❑ NO ❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME <br /> WAINTED 8 SIGNAT AEI DATE <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OFTHE FOU Lpy <br /> COUNTY# <br /> STATE I.D.# JURISDICTION FACILITY# TANK <br /> y <br /> PERMITNUMBER PERMITAPPROVVE BBYI1 ATE PER EXPIRATION GATE 9 J <br /> –� <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A.UNLESS A CURRENT FORMA HAS BEEN FILED. <br /> FORM (12-91) <br /> FILE THIS FORM WITH CAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS ' <br /> FORADHBJN <br />
The URL can be used to link to this page
Your browser does not support the video tag.