COMPACTED SOIL - <br />p SLOPE EXCAVATION OR SHORE TANK <br />-E EXCAVATION PER PROJECT SOILS REPORT, <br />OSHA SOILS CLASSIFICATION AND TANK <br />o MANUFACTURER INSTALLATION <br />INSTRUCTIONS OR PER CIVIL DRAWINGS. <br />ALL SHORING IF REQUIRED TO BE <br />ENGINEERED AND PERMITTED UNDER /\\ <br />o SEPARATE PERMIT BY CONTRACTOR. <br />PEA GRAVEL BEDDING AND BACKFILL TYPICAL TO SUB <br />GRADE SURFACE (BOTTOM OF CONCRETE) <br />NOTE: <br />DEADMEN ARE TO BE PRE CAST ABOVE GROUND AND <br />LOWERED INTO EXCAVATION. <br />NOTE: <br />FILTER FABRIC (DUPONT TYPAR OR MIRAFI 500X) IS <br />REQUIRED FOR ALL INSTALLATIONS. FABRIC MAY BE <br />PINNED TO SIDE OF HOLE WITH WIRE, ETC. SEAMS <br />MUST BE LAPPED 1' MINIMUM. IN WET HOLE <br />INSTALLATIONS FABRIC MUST EXTEND 1' ABOVE MAX. <br />HIGH WATER TABLE. <br />EXTEND CONTINUOUS <br />FILTER FABRIC TO SLAB <br />`- PEA GRAVEL <br />SEE CIVIL SHEETS FOR <br />ADJOINING CONDITIONS <br />C '� 2M�N' <br />T-3 <br />GONG. DEADMEN 18"02" <br />(TYP. OF 2)(T--13 <br />18" WIDE X 2" TALL CONCRETE CROWN <br />(TYP.) <br />3'-0" <br />MIN. <br />30,000 GALLON DOUBLE WALL <br />FIBERGLASS TANK <br />UL 1316 LISTED AND <br />METHANOL COMPATIBLE. <br />10'-6" O.D. <br />O <br />30,000 GALLON DOUBLE WALL <br />FIBERGLASS TANK <br />UL 1316 LISTED AND <br />METHANOL COMPATIBLE. <br />10'-6" 0. D. <br />O <br />3'-O <br />MIN. <br />-f <br />30,000 GALLON DOUBLE WALL <br />FIBERGLASS TANK <br />UL 1316 LISTED AND <br />METHANOL COMPATIBLE. <br />10'-6" 0. D. <br />O <br />GONG. DEADMEN 36"x12", TYP. OF (2) <br />T-3 EXTEND 12" GREATER THAN OVERALL <br />LENGTH OF TANK (TYP.) <br />--- 1S' 0" - 13'-6" T 13'-0" - <br />NOTE: FOLLOW UST MANUFACTURER'S COMPLETE CURRENT INSTALLATION INSTRUCTIONS. <br />OSHA TYPE "C" SIMPLE SLOPE SHOWN IN THIS VIEW <br />-33"--� <br />A Typical Tank Burial <br />T-3 SCALE: 3/8"=V-0" <br />.n--1.1-I--,,-vI, -11 <br />REINFORCED CONCRETE SLAB <br />SEE CIVIL DRAWINGS FOR CONCRETE <br />SPECIFICATIONS. <br />EXTEND CONTINUOUS <br />FILTER FABRIC TO SLAB <br />PEA GRAVEL <br />SEE CIVIL SHEETS FOR <br />ADJOINING CONDITIONS <br />'--� i z <br />COMPACTED SOIL-. <br />FOURTH LIFT OF PEA 5�� WALL OF <br />GRAVEL, FILL TO TOP OF 5 _g / '/ /A/// <br />EXCAVATION <br />TANK X\\�\x INSTALL FILTER FABRIC <br />AT TANK HOLE <br />- (TYP.) <br />THIRD LIFT OF PEA GRAVEL, <br />TAMP GRAVEL BENEATH TANK <br />SECOND LIFT OF PEA GRAVEL, <br />y_ TAMP GRAVEL BENEATH TANK <br />L <br />V -0" -FIRST LIFT OF PEA GRAVEL <br />----- - - " - y- TAMP GRAVEL BENEATH TANK <br />1'-0" TAMPED GRAVEL BED <br />INSTALL FILTER FABRIC <br />AT BOTTOM OF TANK HOLE <br />(TYP.) <br />i 1Vnnnorn Tin nrrrrn,nin <br />0 <br />0 <br />I <br />0 <br />rN INDICATES LIFTING LUG NOTE: <br />NOTE CONTRACTOR SHALL VERIFY EXACT Containment Solutions LOCATION THE TANK FILL END SHALL BE INSTALLED <br />STRAP SPACING WITH TANK MANUFACTURERC 30K Tank Elevation Showing Strap Spacing / t INDICATES STRAP PLACEMENT ONE INCH LOWER IN ELEVATION THAN <br />PRIOR TO HOLD ®OWN CONSTRUCTION. ® INDICATES HOLD DOWN STRAP CLIP THE TANK TURBINE END. <br />-- - - --- �T-3 `,CALE: 1/2"=1'-0' <br />SIDE OF EXCAVATION. <br />18`x12` <br />- 1/4"x3" STRAP WITH GUIDES <br />BY TANK MFG. TO TANK AT <br />ALL DESIGNED LOCATIONS, <br />1/2" GALVANIZED STEEL <br />STRANDED CABLE. <br />#4 REBAR AT EACH <br />CORNER w/ #3 TIES <br />AT 16" O.C. HOLD <br />REBAR 1.5" CLEAR OF <br />FORMED SURFACES. <br />36"x12" <br />B Tank Hold Down Details <br />-3 NOT TO SCALE <br />3/4" GALV. JAW AND EYE TURNBUCKLE. <br />X <br />xM ; <br />TURNBUCKLE LOCATIONS ON EACH TANK <br />L <br />o <br />-I <br />TO ALTERNATE BETWEEN SIDES OF TANK <br />i <br />J <br />z <br />12" MANHOLE 151 <br />m <br />o <br />6" CLEARANCE <br />TANK EXCAVATION OBSERVATION <br />0 <br />BETWEEN CAP <br />PORT (2). INSTALLED WITH TANKS, <br />�1/4"x3' <br />A D GRADE <br />DO NOT DRILL AFTER INSTALLATION. <br />STRAP WITH GUIDES BY <br />;• <br />O <br />TANK MFG, TO TANK AT ALL <br />e� <br />DESIGNED LOCATIONS. <br />154 6" PORT CAP/ PLUG <br />6° PVC <br />J <br />NOTE: ALL EXPOSED GALVANIZED <br />153 <br />COUPLER <br />y�0 <br />STEEL MATERIALS SHALL BE <br />6 SLOTTED <br />`; 6" SOLID PVC PIPING <br />PROPERLY PROTECTED AGAINST <br />152 <br />153 <br />CORROSION WITH COATING OF <br />PVC PIPE <br />r1- <br />BITUMINOUS MATERIAL ONCE. <br />152 PVC CAP <br />INSTALLED. <br />LL <br />?, 6" OBSERVATION PORT DEPTH SHALL BE 24" <br />END OF TANKMINI BELOW TANK. DO NOT PENETRATE SOIL. <br />,L-� DO NOT USE PVC CEMENT ON BOTTOM CAP <br />OR OTHER COUPLINGS OR FITTINGS. <br />E Observation Port Detail <br />T-3 NOT TO SCALE <br />NOTE: <br />SIEVE ANALYSIS OF PEAGRAVEL IS REQUIRED. <br />NOTE: <br />IF GROUNDWATER IS ENCOUNTERED DURING EXCAVATION FOR TANK <br />INSTALLATION OR IF POTENTIAL EXISTS FOR SURFACE RUN-OFF INTO TANK <br />PIT, CONTRACTOR SHALL STRAP THE TANKS TO THE DEADMEN AND BACK <br />FILL TO TOP OF TANKS IMMEDIATELY AFTER TANK PLACEMENT, THEN <br />CONTRACTOR SHALL ENTIRELY FILL TANKS WITH WATER. THE ABOVE, (TANK <br />BALLAST & PLACEMENT BY FILLING WITH WATER) SHALL BE DONE IN ONE <br />CONTINUOUS PROCESS. TANKS SHALL BE PUMPED DRY ONLY AFTER FINAL <br />BACK FILL AND CONCRETE COVER IS IN PLACE. <br />58.25 <br />r <br />7" CONCRETE SLAB AT <br />87.6 LB/CF <br />4' DIA. <br />SUMP <br />0 TANK 4' MIN. BURY DEPT <br />10.5' DIA. <br />13,900 LBS <br />EMPTY <br />21,000 LBS I- 4 1.5' GRAVEL COLUMN <br />BRINE FILLED <br />O <br />5 1' X 1.5' X 55.25' <br />+ DEADMAN <br />1-12" <br />TOTAL HOLD DOWN: 369.272 LBS _ 1.45 SAFETY FACTOR <br />TOTAL TANK UPLIFT: 254,997 LBS <br />BUOYANCY CALCULATION, 30,000 GAL. TANK <br />CALCULATION BASED ON SUBMERGED WEIGHT OF MATERIALS: <br />"CONTAINMENT SOLUTIONS" TANK WITH SPHERICAL ENDS, <br />(10' NOMINAL) <br />TANK LENGTH: 54'-3" TANK DIAMETER 10'-6" <br />TRY 55'-3" DEADMAN, EACH SIDE, 18" WIDE X 12" HIGH <br />EMPTY TANK UPLIFT = 29,816 GAL _ 3986 CU FT <br />7.48 GAL./CF <br />3986 CU FT X 62.4 LBS/CF = 248,726 LBS (DISPLACED WATER) <br />TANK SUMP UPLIFT = (2) X 3.14 X 2'2X 4' = 100.5 CU FT <br />100.5 CF X 62.4 LBS/CU FT = 6271 LBS (DISPLACED WATER) <br />TOTAL TANK UPLIFT = 248,726 LBS + 6,271 LBS = 254.997 LBS <br />HOLD DOWN CALCULATION <br />TANK SLAB: .58' X 13.5' X 58.25' = 456 CU FT X 87.6/CF <br />456 CU FT X 87.6 LBS/CU FT = 39.945 LBS 1 <br />CUBED BACKFILL ABOVE TANK: r <br />4'X 10.5' X54.25'=2,278.5 CU FT- 100.5 CUT=2,178 CU FT <br />2,178.0 CU FT X 57.6 LBS/ CU FT = 125.453 LBS <br />CURVED BACKFILL ABOVE TANK: <br />3.14 X 5.25'2X 54.25' = 4,695 CU FT <br />10,5' X 10.5' X 54.25' = 5,981 CU FT <br />5981 CU FT - 4695 CU FT = 1286 2 CU FT = 643.0 CU FT <br />643.0 CU FTX 57.6 LBS/ CU FT = 37.037 LBS <br />(44] GRAVEL COLUMN ABOVE DEADMEN: <br />1.5' X 14.5' X 55.25' X 2 = 2,403 CU FT <br />2,403 CU FT X 57.6 LBS/ CU FT = 138.413 LBS <br />0 CONCRETE DEADMEN: <br />1' X 1.5' X 55.25' = 82.9 CU FT <br />82.9 CU FT X 87.6 LBS/ CU FT X (2) = 14.524 LBS <br />DRY WEIGHT TO TANK: 13,900 LBS <br />TOTAL HOLD DOWN: 369.272 LBS <br />Buoyancy Calculation 30,000 Gallon Tank <br />T-3 NOT TO SCALE <br />W n <br />J <br />WW <br />Wa00 <br />rn <br />O <br />2W <br />/3B2 <br />0 <br />O <br />O� <br />U <br />X <br />xM ; <br />0 <br />L <br />o <br />-I <br />LL <br />i <br />J <br />z <br />� <br />m <br />o <br />Q <br />0 <br />W <br />U <br />rn <br />O <br />LUT <br />O <br />CC <br />cc C\1 <br />O <br />QQpV_ESSIONq <br />J <br />y�0 <br />Z� <br />HAL U8B <br />U <br />B <br />Z <br />T <br />w,• <br />C I V <br />® <br />LL <br />U <br />WZ <br />fr <br />O <br />az <br /><�- <br />Z <br />o <br />Q <br />= <br />Q <br />O <br />W <br />U <br />:0i� <br />Q�I� <br />N <br />Zcm <br />COI <br />V <br />Jc7OO <br />` <br />a/y� <br />J <br />0 <br />Y <br />N <br />/ <br />cr <br />f1 / <br />O <br />o <br />Ln <br />U <br />o <br />Q <br />NOTE: <br />SIEVE ANALYSIS OF PEAGRAVEL IS REQUIRED. <br />NOTE: <br />IF GROUNDWATER IS ENCOUNTERED DURING EXCAVATION FOR TANK <br />INSTALLATION OR IF POTENTIAL EXISTS FOR SURFACE RUN-OFF INTO TANK <br />PIT, CONTRACTOR SHALL STRAP THE TANKS TO THE DEADMEN AND BACK <br />FILL TO TOP OF TANKS IMMEDIATELY AFTER TANK PLACEMENT, THEN <br />CONTRACTOR SHALL ENTIRELY FILL TANKS WITH WATER. THE ABOVE, (TANK <br />BALLAST & PLACEMENT BY FILLING WITH WATER) SHALL BE DONE IN ONE <br />CONTINUOUS PROCESS. TANKS SHALL BE PUMPED DRY ONLY AFTER FINAL <br />BACK FILL AND CONCRETE COVER IS IN PLACE. <br />58.25 <br />r <br />7" CONCRETE SLAB AT <br />87.6 LB/CF <br />4' DIA. <br />SUMP <br />0 TANK 4' MIN. BURY DEPT <br />10.5' DIA. <br />13,900 LBS <br />EMPTY <br />21,000 LBS I- 4 1.5' GRAVEL COLUMN <br />BRINE FILLED <br />O <br />5 1' X 1.5' X 55.25' <br />+ DEADMAN <br />1-12" <br />TOTAL HOLD DOWN: 369.272 LBS _ 1.45 SAFETY FACTOR <br />TOTAL TANK UPLIFT: 254,997 LBS <br />BUOYANCY CALCULATION, 30,000 GAL. TANK <br />CALCULATION BASED ON SUBMERGED WEIGHT OF MATERIALS: <br />"CONTAINMENT SOLUTIONS" TANK WITH SPHERICAL ENDS, <br />(10' NOMINAL) <br />TANK LENGTH: 54'-3" TANK DIAMETER 10'-6" <br />TRY 55'-3" DEADMAN, EACH SIDE, 18" WIDE X 12" HIGH <br />EMPTY TANK UPLIFT = 29,816 GAL _ 3986 CU FT <br />7.48 GAL./CF <br />3986 CU FT X 62.4 LBS/CF = 248,726 LBS (DISPLACED WATER) <br />TANK SUMP UPLIFT = (2) X 3.14 X 2'2X 4' = 100.5 CU FT <br />100.5 CF X 62.4 LBS/CU FT = 6271 LBS (DISPLACED WATER) <br />TOTAL TANK UPLIFT = 248,726 LBS + 6,271 LBS = 254.997 LBS <br />HOLD DOWN CALCULATION <br />TANK SLAB: .58' X 13.5' X 58.25' = 456 CU FT X 87.6/CF <br />456 CU FT X 87.6 LBS/CU FT = 39.945 LBS 1 <br />CUBED BACKFILL ABOVE TANK: r <br />4'X 10.5' X54.25'=2,278.5 CU FT- 100.5 CUT=2,178 CU FT <br />2,178.0 CU FT X 57.6 LBS/ CU FT = 125.453 LBS <br />CURVED BACKFILL ABOVE TANK: <br />3.14 X 5.25'2X 54.25' = 4,695 CU FT <br />10,5' X 10.5' X 54.25' = 5,981 CU FT <br />5981 CU FT - 4695 CU FT = 1286 2 CU FT = 643.0 CU FT <br />643.0 CU FTX 57.6 LBS/ CU FT = 37.037 LBS <br />(44] GRAVEL COLUMN ABOVE DEADMEN: <br />1.5' X 14.5' X 55.25' X 2 = 2,403 CU FT <br />2,403 CU FT X 57.6 LBS/ CU FT = 138.413 LBS <br />0 CONCRETE DEADMEN: <br />1' X 1.5' X 55.25' = 82.9 CU FT <br />82.9 CU FT X 87.6 LBS/ CU FT X (2) = 14.524 LBS <br />DRY WEIGHT TO TANK: 13,900 LBS <br />TOTAL HOLD DOWN: 369.272 LBS <br />Buoyancy Calculation 30,000 Gallon Tank <br />T-3 NOT TO SCALE <br />W n <br />J <br />WW <br />Wa00 <br />rn <br />O <br />2W <br />/3B2 <br />0 <br />O <br />O� <br />U <br />Yj <br />Mi <br />X <br />xM ; <br />0 <br />L <br />o <br />-I <br />LL <br />i <br />pa <br />z <br />� <br />LL <br />o <br />Q <br />0 <br />W <br />U <br />rn <br />O <br />LUT <br />O <br />CC <br />cc C\1 <br />O <br />QQpV_ESSIONq <br />y�0 <br />HAL U8B <br />II <br />B <br />6/30/0 <br />T <br />w,• <br />C I V <br />Yj <br />Mi <br />> <br />o <br />xM ; <br />Ui <br />m, <br />o <br />z <br />° <br />i <br />pa <br />z <br />� <br />z <br />o <br />x <br />Yj <br />Mi <br />> <br />o <br />xM ; <br />Ui <br />m, <br />3 <br />v <br />pa <br />N <br />v <br />0 5` <br />0 <br />w <br />a <br />a <br />� zw <br />w N N N g Z <br />C, <br />C, co 00 z & <br />m �w <br />NQin u] z <br />N CMZ <br />Ln zL <br />w <br />z v) in <br />WLLJ <br />Y U U <br />s <br />Jv <br />