My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1986-1994
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SCOTTS
>
935
>
2300 - Underground Storage Tank Program
>
PR0231250
>
BILLING 1986-1994
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2024 1:57:12 PM
Creation date
11/6/2018 1:20:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1986-1994
RECORD_ID
PR0231250
PE
2381
FACILITY_ID
FA0003913
FACILITY_NAME
INDUSTRIAL INNOVATIONS
STREET_NUMBER
935
Direction
E
STREET_NAME
SCOTTS
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
15128031
CURRENT_STATUS
02
SITE_LOCATION
935 E SCOTTS AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SCOTTS\935\PR0231250\BILLING 1986-1994.PDF
QuestysFileName
BILLING 1986-1994
QuestysRecordDate
9/8/2017 6:31:37 PM
QuestysRecordID
3630906
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• STATE OF CALIFORNIA • •cspOR, co <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> COMPLETE ASEPARATE FORM FOR EAC9 TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT3 RENEWAL PERMIT <br /> ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED <br /> /S <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: 2'31— r S,Cd ff S S, fT/7+ <br /> I. TANK DESCRIPTION CO EA ITE - SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.# O S/ B. MANUFACTURED BY: u�L_ <br /> C. DATE INSTALLED(MO/DAY/YEAR) D. TANK CAPACITY IN GALLONS: <br /> ILTANKCONTENTS IFA-11SMARKED,COMPLETE ITEM C. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. 7PRDUCT <br /> C is REGULAR o 3 DIESEL <br /> ❑ 2 PETROLEUM SO PT. ❑ UNLEADED PREMIUM ❑ 4 GASAHOL ❑ 6 AVIATION GAS <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ ❑ 16UNLEADED ❑ 5 JET FUEL ❑ 7 METHANOL <br /> ❑ ❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OFSUBSTANCE STORED <br /> C.A.S.# <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXESA,B,AND C.AND ALL THAT APPLIES IN BOX <br /> A. TYPE OF ❑ 1/ UBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER <br /> L1��,/ ❑ 95 UNKNOWN <br /> SYSTEM 2 SING WALL ❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) ❑ 99 OTHER <br /> S. TANK 1 R ST ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCEDPLASTIC <br /> MATERI 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ B 100% METHANOL COMPATIBLE W/FRP <br /> (PrlmaryTan ❑ 9 BRON ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> 1 RUBBER LINED 2 ALKYD LINING <br /> C.INTERIOR ❑ 3 EPDXY LINING p 4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING ❑ 6 UNLINED ❑ 95 UNKNOWN 99 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 10D% METHANOL? YES_ NO <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> IV.PIPING INFORMATION CIRCLE A IFASOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U i SUCTION A U 2 PRESSURE A U 3 GRAVITY ACU 99 OTHER <br /> B. CONSTRUCTION A 1 SINGLE W L A U 2 DOUBLE WALL p U 3 LINED TRENCH q U 95 UNKNOWN <br /> A U 99 OTHER <br /> C. MATERIAL AND A U 7 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM 6 CONCRETE A U 7 STEELW/COATING <br /> A U B 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL <br /> A U 10 CATHODIC PROTECTION p U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ 31NTERST KL <br /> MONITORING ❑98 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 POR MONITORING❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> ❑ e TANK TESTING ❑ 7 INTERSTITIALMONITORING B7 NONE ❑ 96 UNKNOWN <br /> ED99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> L <br /> p AC-1,f17 / / SUBSTANCE REMAINING GALLONS I INERTMATERIAL7 YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> APPLICANT'S NAME <br /> (PRINTED 8 SIGNATURE) QATE <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> STATE I.D.# <br /> COUNTY# JURISDICTION# FACILITY# TANK <br /> �R `/ <br /> .ySO -3 <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPI TI 14 DATE <br /> i4y/Y3 <br /> FORM B(9.90) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FOR00108414 <br />
The URL can be used to link to this page