My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SIERRA NEVADA
>
1145
>
2300 - Underground Storage Tank Program
>
PR0231243
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2024 3:38:17 PM
Creation date
11/6/2018 1:37:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0231243
PE
2361
FACILITY_ID
FA0004068
FACILITY_NAME
GBM Manufacturing Inc.
STREET_NUMBER
1145
Direction
S
STREET_NAME
SIERRA NEVADA
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15135027
CURRENT_STATUS
02
SITE_LOCATION
1145 S SIERRA NEVADA ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SIERRA NEVADA\1145\PR0231243\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
8/21/2017 5:41:36 PM
QuestysRecordID
3596301
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PNIFIED PROGRAM CONSOLIDATED FOR` <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> A.PIPING CONSTRUCTION(Check a¢tAeleppy) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE 1. PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY ❑ 1. PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY <br /> CONSTRUCTION/ ❑ 1. SINGLE WALL ❑ 3. LINEDTRENCH ❑99. OTHER ❑ 1. SINGLE WALL ❑95. UNKNOWN <br /> MANUFACTURER 2. DOUBLE WALL ❑95. UNKNOWN ❑ 2. DOUBLE WALL 1199. OTHER <br /> MANUFACTURER MANUFACTURER <br /> ❑ 1.BARE STEEL ❑ S. FRP COMPATIBLE W/10o%METHANOL ❑ 1. BARE STEEL ❑ 0. FRP COMPATIBLE W/100%METHANOL <br /> MATERIALSAND ❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL ❑ 2. STAINLESS STEEL ❑ T. GALVANIZED STEEL <br /> CORROSION <br /> 13 `N 3. <br /> PROTECTION 3. PLASTIC COMPATIBLE WITH CONTENTS ❑95. UNKNOWN ❑ PLANTH COMPATIBLE TH CONTENTS 11 B. FLEXIBLE(HOPE) ❑N. OTHER <br /> ❑ 4. FIBERGLASS ❑ 0. FLEXIBLE(HDPE) 1199. OTHER ❑ T FIBERGLASS ❑ 9. CATHODIC PROTECTION <br /> ❑ <br /> S. STEEL W/COATING ❑ 9. CATHODIC PROTECTION ❑ 5. STEEL W/COATING ❑95. UNKNOWN <br /> VII.PIPING LEAK DETECTION(Check ad that appy) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING SINGLE WALL PIPING <br /> PRESSURIZED PIPING(Check aB that appM' PRESSURIZED PIPING(Check aN that appy): <br /> ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPM TEST WITH AUTO PUMP SHUT OFF FOR ❑ I. ELECTRONIC LME LEAK DETECTOR 3.0 GPM TEST PATH AUTO PUMP SHUT OFF FOR LEAK, <br /> LEAK,SYSTEM FAILURE.AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION;AUDAUDIBLE AND VISUAL ALARMS <br /> ALARMS ❑ 2. MONTHLY 0.2 GPM TEST <br /> ❑ 2 MONTHLY 0.2 GPM TEST <br /> ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPM) ❑ 3. ANNUAL VI UAL CHECK TEST(0.1 CPN) <br /> ❑ 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS'. CONVENTIONAL SUCTION SYSTEMS(Chxk all Met apply): <br /> ❑ 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY ❑ S. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPM) ❑ 0. TRIENNIAL INTEGRITY TEST(0.1 GPM) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING) SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> ❑ T. SELF MONITORING ❑ 7. SELF MONITORING <br /> GRAVITY FLOW'. GRAVITY FLOW(Check all that appy)' <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPM) a ❑ 0. DAILY VISUAL MONITORING <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPM) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that appy): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10.CONTINUOUS TURBINE SUMP SENSOR NTH AUDIBLE AND VISUAL ALARMS AND(cNeok one) <br /> (Check one) <br /> rl a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ is AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> �a AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ E, AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> ❑ c. NO AUTO PUMP SHUT OFF ❑ c. NO AUTO PUMP SMUT OFF <br /> 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPM TEST)NTH FLOW SHUT OFF OR ❑ 11. AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> ❑ 12. ANNUAL NTEGRITY TEST(0 1 GPM) ❑ 12.ANNUAL INTEGRITY TEST(0 t GPM) <br /> SUCTION/GRAVITY SYSTEM: SUCTION/GRAVITY SYSTEM: <br /> ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check as that appy) EMERGENCY GENERATORS ONLY(Check all Mat appy) <br /> ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUOIBLE AND ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUAL ALARMS ALARMS <br /> ❑ 15. AUTOMATIC LINE LEAH DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPM TEST) <br /> RESTRICTION <br /> ❑ 18. ANNUAL INTEGRITY TEST(0.1 GPM) ❑ 10. ANNUAL INTEGRITY TEST(0.1 GPM) <br /> ❑ 17. DAILYVISVALCHECK ❑ 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑ 1. FLOAT MECHANISM THAT SHUTS OFF SMEAR VALVE ❑ 4. DAILY VISUAL CHECK <br /> DATE INSTALLED ❑ 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5. TRENCH LINER/MONITORING <br /> ❑ 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS B. NONE <br /> IX.OWNER/OPERATOR SIGNATURE <br /> 1 canary Mel Me Information provided Ismaili is Wa and ie=rate to Me East of my Mowled9e. <br /> SIGNATURE OF OMMERIOPERATOR DATE <br /> NAME OF OWNEWOPERATOR(hill TITLE OF OWNER/OPERATOR <br /> Permit Number/For local um Dory) Permit Apprnaed(Ferlocal use only) Permit Expirabon Date(Forlocal use amyl <br /> CUPAFORM(4/99) • • Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.