My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SIERRA NEVADA
>
1145
>
2300 - Underground Storage Tank Program
>
PR0231243
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2024 3:38:17 PM
Creation date
11/6/2018 1:37:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0231243
PE
2361
FACILITY_ID
FA0004068
FACILITY_NAME
GBM Manufacturing Inc.
STREET_NUMBER
1145
Direction
S
STREET_NAME
SIERRA NEVADA
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15135027
CURRENT_STATUS
02
SITE_LOCATION
1145 S SIERRA NEVADA ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SIERRA NEVADA\1145\PR0231243\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
8/21/2017 5:41:36 PM
QuestysRecordID
3596301
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA �� ac*� <br /> STATE WATER RESOURCES CONTROL BOARD +Y'd� d e <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION-FORM B > - , <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY I NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br /> ONE REM 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 6 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: ! ! ce. �—� <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A OWNER'S TANK I.D.# 3 B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MOMAYA'EAR) V—3— 8 D. TANK CAPACITY IN GALLONS: a- O <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> A <br /> ❑ 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C. 0 1a REGULAR UNLEADED 3 DIESEL ❑ 6 AVIATION GAS <br /> 2 80 EMPTY PRODUCT <br /> E] lb PREMIUM UNLEADED 4 GASAHOL ❑ 7 METHANOL <br /> PETROLEUM <br /> ❑ ❑ ❑ 1c MDGRADE UNLEADED ❑ 5 JET FUEL ❑ 8 M85 <br /> ❑ 3 CHEMICALPRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER(DESCRIBE IN ITEMD.BELom <br /> 0. IF(A.1)IS NOT MARKED, ENTER NAME OFSUBSTANCE STORED C.AS#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A B AND C.AND ALL THAT APPLIES IN BOX D AND <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK ❑ I BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS 02-14�STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ a POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 1001/6 METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑^/2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING D2 ° UNLINED ❑ 9!5,UNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP E 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION ❑ gl NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> PROTECTION ❑ 5 CATHODIC PROTECTION92 <br /> SPILL CONTAINME STALLED(YEAR) OVERFl L REVENTION EQUIPMENT INSTALLED(YEAR) <br /> E.SPILL AND OVERFILL,etc. DROPtr YES NO_ SX IKERPLATEYES NO_ DISPENSER CONTAINMENT VES_ NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A E2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A&/2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A Q 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE WffRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> 1 IECN411UL LME IFAK 3 4 RE <br /> MTK+MNE58 CgmNWll9 INIERSIrtIAL CTILONIC UNE ❑5 A.U=TC RIMP ❑ <br /> D. LEAK DETECTION 2❑ �ODg ❑ resnx0 ❑ MDMraRNo ❑ IEAx oETEcroR sRurMraN 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ED VISUAL CHECK ❑ 2 ERCOLI CILIATIONORY ❑ 3 MAODNOITORING ZE ❑ 4 GAUGWGAUTOMATIC TANK ❑ 5 MON TORINGGROUND TER ❑8 TESTIANNUAL NG <br /> 7 CONTINUOUS INTERSTITIAL ❑ g SIR ❑ 9 WEEKLY MANUAL E::]10 MONTHLY TANK ❑ 95 UNKNOWN ❑ 99 OTHER <br /> MONITORING TANK GAUGING <br /> TING <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PUCE) <br /> 1.ESTIMATED DATE MdDAWYR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO❑ <br /> SUBSTANCE REMAINING GALLONS INERTMATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK OWNERS NAME DATE <br /> (PRIMED d SIDNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TA® <br /> STATE I.D.# c. = <br /> PERMIT NUMBER PERMIT APPROVED SYMATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS ACURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOTp FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE U ERGROUND STORAGETANKREGULATIONS <br /> FORMS (6-95) f -77 7 " <br />
The URL can be used to link to this page
Your browser does not support the video tag.