My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SIERRA NEVADA
>
1145
>
2300 - Underground Storage Tank Program
>
PR0231243
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2024 3:38:17 PM
Creation date
11/6/2018 1:37:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0231243
PE
2361
FACILITY_ID
FA0004068
FACILITY_NAME
GBM Manufacturing Inc.
STREET_NUMBER
1145
Direction
S
STREET_NAME
SIERRA NEVADA
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15135027
CURRENT_STATUS
02
SITE_LOCATION
1145 S SIERRA NEVADA ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SIERRA NEVADA\1145\PR0231243\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
8/21/2017 5:41:36 PM
QuestysRecordID
3596301
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT <br /> 304 E.Weher Ave.,Thud Floor•Stodmon,CA 95202-2708• Phone(209)468-3420 <br /> Donna Heran,R.E.H.S.,Director <br /> ENVIRONMENTAL HEALTH <br /> SAN JOAQUIN COUNTY CERTIFIED UNIFIED PROGRAM AGENCY <br /> PERMIT TO OPERATE <br /> Program Permit <br /> Record ID Number Program Code and Description Permit <br /> Valid <br /> PR023124 2300•UNDERGROUND STORAGE TANK FACILITY 1/1/2002 To 12/31/2002 <br /> Underground Storage Tank Program, <br /> California Health and Safety-C-o--d-e Div.20,Chap_6.7 and Tide-2--3--Cal ifomia_Code of Regulations Chap_16. <br /> FOE Tank# Tank Record ID Permit# Capacity Contents Permit Status System Type Leak Detection <br /> 2362 3 390002312430124303 PT0006629 12,000 DIESEL Active,billable DOUBLE WALLED Comnuous Interstitial <br /> Monitoring <br /> Underground Storage Tank Permit Conditions <br /> 1) The Permit to Operate will become void if Annual Permit Fees and Service Fees are not paid and/or the UST system(s)fails to remain in compliance with these Permit Conditions. <br /> 2) In order to maintain the operating perrmq the owner and operator shall comply with the H&S Code,Div.20,Chap.6.7 and 6.75;and CCR Title 23,Chap.16 and 18,as well as any <br /> conditions established by San Joaquin County, <br /> 3) If the Tank Operator(s)is different from the Tank Owner,or if the Permit to Operate is issued to a person other than the owner or operator of the tank,the Permittee shall ensure that <br /> both the Tank Owner and tank Operator receive a copy of the permit <br /> 4) Written Monitoring Procedures and an Emergency Response Plan most be approved by the Environmental Health Department(EHD)and are considererd UST Permit Conditions. The <br /> approved monitoring,response,and plot plans shall be maintained onsite with the pend[ <br /> 5) The Permittee shall comply with the monitoring procedures referenced in this permit. <br /> 6) The Permittee shall perform testing and preventive maintenance on all leak detection monitoring equipment annually,or more frequently if specified by the equipment manufacturer, <br /> and provide documentation of such servicing to this office. <br /> 7) In the event of a spill,leak,or other unauthorized release,the Permitee shall comply with the requirements of Title 23 CCR Chap.16,ArL 5,and the approved Emergency Response <br /> Plan. <br /> 8) Written records of all monitoring performed shall be maintained on-site by the operator and be available for inspection for a period of at least three years from the date the monitoring <br /> was performed. <br /> 9) The EHD shall be notified of any change in ownership or operation of the UST system within 30 days of such change. <br /> 10) Upon any change in equipment,design or operation of the UST system(including change in tank contents or usage),the Permit to Operate will be subject to review,modification or <br /> revocation. <br /> 11) Construction,repair and/or remcm]permits are required from the EHD prior to any change,repair or removal of UST system equipment <br /> 12) The Permittee shall submit an annual report documenting compliance with the UST Permit Conditions within 30 days of the anniversary date of the issuance of this permit. <br /> 13) This Permit to Operate shall not be considered permission to violate any laws,ordinances or statutes of my other Federal,State or Local agency. <br /> 14) A"Conditional"Permit may be revoked if corrections specified on the inspection report are not completed by the date(s) indicated. <br /> PERMITS TO OPERATE are NOT TRANSFERABLE <br /> and may be SUSPENDED or REVOKED for cause. <br /> PERMIT(s)Valid only for: ANGELICA TEXTILE SERVICES <br /> Tank Owner: ANGELICA WESTERN RENTAL <br /> THIS FORM MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES <br /> Regulated Facility. ANGELICA TEXTILE SERVICES Facility ID FA0004068 <br /> 1145 S SIERRA NEVADA ST Account ID AR0003724 <br /> STOCKTON. CA 95205 Issued 3129/2002 <br /> Billing Address: ATTN : ANGELICA TEXTILE SERVICES <br /> ANGELICA TEXTILE SERVICES <br /> 700 ROSEDALE AVE <br /> ST. LOUIS, MO 63112-1408 <br /> 7023.rpt <br />