Laserfiche WebLink
aOARD OF TRUSTEES SAN JO LOCAL HEALTH DISTRICT• <br /> Jsmea Culbertson, Pres. r SERVIHO <br /> Patricia E. Vannuccl, Secy. City of Lodi <br /> Anthonall• Van Sproneen 1601 East Hazelton Avenue, P. O. Box 2009 San Joaquin County <br /> Earl Plmenlel Stockton,Call four le 95201 City of Escalon <br /> Fern 8udt»e - City of Manteca <br /> Daniel L. Flora 209/466-6781 City of Ripon <br /> John D. Meat, M.D. City of Stockton <br /> William J. Wada Jog[ Khanna, M.O., M.P.H., District Health 011lcer City of Tracy <br /> Mary Anna Low San Joaquin County <br /> San Joaquin County <br /> Facility Name SO( 1+,--\e4-Y" P Lt �, C- Tia <br /> Address & , -{'t--\- re + <br /> Date of Inspection oZcl—$ 7 Inspector _ rp�ct l �gprl <br /> MONITORING ALTERNATIVE N7 <br /> Limited to underground storage tanks which have infrequent inputs and withdrawals and <br /> where the ligllic: level in the tank can be measured to an accuracy of +5 gallons or less <br /> when the tank is half full . <br /> This monitoring alternative shall include: <br /> L/Annual precision test on tank and piping. <br /> k/ Tank gauging performed as follows: <br /> �Tdnk must be capable of being secured to prevent unauthorized inputs and <br /> withdrawals. <br /> I/ Tank must have no inputs or withdrawals for at least a 48 hour period <br /> (2 days) at the end of consecutive periods lasting up to 7 days. <br /> (For example: tank in use Monday through Friday, then locked <br /> over weekend) . <br /> Liquid level measurements are taken at the beginning and end of the <br /> monitoring period (lasting at least 48 hours). <br /> (For example : level measured and recorded Friday night before <br /> locking and again on Monday morning before opening. ) <br /> V If liquid level varies more than 1% of the tank volume or 5 gallons , which <br /> ever is less , between measurements, an unauthorized release shall be <br /> assumed to have occurred and shall be reported to the local agency within <br /> 24 hours , as per Article 5, Sect. 2652 of the regulations and further <br /> evaluations shall be performed to verify or disprove the variations. <br /> Implementation of the monitoring alternative requires that the following circled items be <br /> completed by the dates specified. <br /> Precision test(s) must be performed by -; —J�'0vv <br /> -7and results submitted to this <br /> office within 30 days of the test. <br /> Tank gauging must be started immediately. (See instructions above), <br /> If the above compliance dates cannot be met, contact this office prior to the specified <br /> date. <br /> 4/86 UGT 3 <br />