Laserfiche WebLink
13 <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS c <br /> UNDERGROUND STORAGE TANKS- TANK PAGE 1 s�I ��° <br /> ai 3 a / (Two pages per tank) <br /> 0T <br /> Page_of_ V a <br /> TYPE OF ACTION ❑ 1.NEW PERMIT ❑ 4.AMENDED PERMIT ❑ 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one item only) ❑ 3.RENEWAL PERMIT ❑ 7.PERMANENTLY CLOSED ON SITE �t <br /> (Specify re..) (Specify reason) 8.TANK REMOVED e <br /> BUSINESS NAME(Smne ae FACILITY NAME or DBA-Doing Buemers As) 3. FACILITY u�, 1. <br /> s 's �l r F /7 15 c� 3 <br /> LOCATION WITHIN SI E fops ref) 43114 _l <br /> I.TANK DESCRIPTION <br /> (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# '757 432 TANK MANUFACTURER 433. COMPARTMENTALIZED TANK ❑Yes C5 No 434 <br /> US'T- \ Un If r If'Yee,complete one pageto,eachcompere.t. <br /> DATE INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS 437 <br /> (YEAR/MO) <br /> V31Kno4„n <br /> ADDITIONAL DESCRIPTION(For low we only) 439. <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440. <br /> $( 1. MOTOR VEHICLE FUEL 1Z In. REGULAR UNLEADED $2. LEADED [IS. JET FUEL <br /> (If checkd,compine Peaoleum Type) ®lb. PREMIUM UNLEADED J13. DIESEL ❑6. AVIATION GAS <br /> [1 2. NON-FUEL PETROLEUM 53 to. MIDGRADE UNLEADED ❑4. GASOHOL OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (8rom Hacodow Materials Inventory page) 441. CAS#(from Humdmm Metenah Inventory page) 441. <br /> ❑ 4. HAZARDOUS WASTE <br /> (Includes UsM Oil) <br /> ❑ 95.UNKNOWN <br /> IIL TANK CONSTRUCTION <br /> TYPE OF TANK Pr I. SINGLE WALL [13. SINGLE WALL WITH EXTERIOR ❑S. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> 2. DOUBLE WALL ❑4. SINGLE WALL IN A VAULT 99. OTHER <br /> TANK MATERIAL-primuy look I I. BARE STEEL ❑3. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95.UNKNOWN 444. <br /> (Chmk one itemonly) ❑2. STAINLESS STEEL [34. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE [199.OTHER: <br /> REINFORCED PLASTIC W/100%METHANOL <br /> TANK MATERIAL-secondary tank [11. BARE STEEL 3. FIBERGLASS/PLASTIC N. FRP COMFTTBLE W/100%METHANOL ❑95.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL❑4. STEEL CLAD W/FIBERGLASS [19. FRP NDN-CORRODABLE JACKET [199.OTHER <br /> REINFORCED PLASTIC(FRP) [110. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING [11.RUBBER LINED 3.EPDXY LINING Ll 5.GLASS LINING 95.UNKNOWN W. DATE INSTALLED 447. <br /> OR COATING [12.ALKYD LINING [14.PHENOLIC LINING [16.UNLINED ❑99.OTHER <br /> Check one item onl <br /> OTHER CORROSION 1.MANUFACTURED CATHODIC ❑3.FIBERGLASS REINFORCED PLASTIC 9 95.UNKNOWN 449. DATE INSTALLED 449, <br /> PROTECTION PROTECTION El 4.IMPRESSED CURRENT [199.OTHER <br /> If livable ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 450. TYPE 451. OVERFILL PROTECTTONEQUIPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) [It.SPILL CONTAINMENT [11.ALARM [13.FILL TUBE SHUT OFF VALVE_ <br /> [12.DROP TUBE ❑2.BALL FLOAT_❑4.EXEMPT <br /> [13.STRIKER PLATE <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453. IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑1. VISUAL(EXPOSED PORTION ONLY) ❑S.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2.AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE ❑2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> ❑4.STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99.OTHER <br /> _ K CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTTM. DATE LAST USED(YR/MO/D Y)� 055' ESTTMATEDQUANTITY OF SUBSTANCE REMAINING 456' TANK FILLED WITH INERT MATERIAL? 45Z <br /> P gallons ❑Yes ❑ No <br /> UPCF hwfivrc-b(W9).114 hep://www.unidoo.org Rev.02/16/00 <br />