My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1994-2010 (2)
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
STOCKTON
>
239
>
2300 - Underground Storage Tank Program
>
PR0231482
>
COMPLIANCE INFO 1994-2010 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:39:57 PM
Creation date
11/6/2018 2:38:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1994-2010
RECORD_ID
PR0231482
PE
2361
FACILITY_ID
FA0000720
FACILITY_NAME
MADSENS SUNRISE DAIRY
STREET_NUMBER
239
Direction
S
STREET_NAME
STOCKTON
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
25927805
CURRENT_STATUS
02
SITE_LOCATION
239 S STOCKTON ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\STOCKTON\239\PR0231482\COMPLIANCE INFO 1994-2010.PDF
QuestysFileName
COMPLIANCE INFO 1994-2010
QuestysRecordDate
9/25/2017 6:59:08 PM
QuestysRecordID
3647880
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
156
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY DATE 11110 16 <br /> VE- <br /> VIRONMENTAL HEALTH DEPART/ T PR# <br /> Weber Ave., Third Floor, Stockton, CA 5202 PAGE <br /> (209)468-3420 <br /> UNDERGROUND STORAGE:TANK (UST)_PROGRAM INSPECTION REPORT <br /> Facility Name.M,445Q4,)'5 5uvT--ix D.4 Facility Address C1 <br /> Facilty Contact IA4 II Titled A. - Phone # � <br /> UST# Product UST# Product V L- UST#(-.� Produc# /1ST# Product <br /> Overfill Prevention: ❑AudibleNisual X.Mechanical Monitoring Panel: CC'Pj <br /> Piping System: ❑ Gravity El Pressure XSuction Violations: ❑ M1-RDet 11 M2-Rprev ❑ M3-Both <br /> Automatic Pump Shut Down Satisfies CCR 2636 f)(5): ❑ Yeso Designated Operator: <br /> [INSPECTION TYPE: ,KRoutine Wonitoring Certification LComplaint ❑Install ❑Removal `Repair/Upgrade <br /> COMPANY NAME: XU Fe-Gk TECHNICIAN NAME: AAF PHONE: � 7 — 232 p <br /> VIOLATION(S) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSG) and/or <br /> California Code of Regulations (CCR): <br /> 1 HSC 25284 Permit to operate 23 CCR 2643 (d) Daily monitoring of suction <br /> 2 CCR 2637 Secondary cont. testing piping (pre-1/1/84) <br /> 3 CCR 2711(b) & (c) Current State Forms A& 8 24 CCR 2636 (a) Conventional suction piping <br /> 4 HSC 25292.2 Certification of financial shall have continuous <br /> responsibility& CFO letter monitoring & 20 containment <br /> 5 CCR 2632 (c)(2) UST monitoring is present (M1) 25 CCR 2643 (e) Biennial tightness test of gravit, <br /> 6 CCR 2630 (d) UST system monitoring piping (pre 111184) <br /> equipment is properly located to 26 CCR 2643 (d) Triennial line test for <br /> detect a leak(M1) conventional suction (pre- <br /> 7 CCR 2637(b) UST system monitoring 1/1/84) (M1) <br /> equipment is operational (M1) 27 CCR 2661 Permit to repair UST system <br /> 8 CCR 2636 (f)(1) Continuous monitoring system 28 HSC 25286 (a) Permit to alter monitoring <br /> for underground piping & UDC system <br /> is present(M1) 29 HSG 25298 (a) Illegal abandonment of UST <br /> 9 CCR 2636 (c)(1) All releases in secondary piping system <br /> flow to a collection sump 30 HSG 25298 (b) Permit to temporarily close US- <br /> 10 HSC 25291 (f) Line leak detector(s) (M1) system <br /> 11 HSC 25291(a)(2) Secondary containment for 31 HSC 25298 (c) Permit to close UST system <br /> UST is tight 32 HSC 25292.1 UST system is operated to <br /> 12 CCR 2635 (b)(1) Spill container(M2) prevent unauthorized release <br /> 13 HSC 25284.2 Annual spill container testing 33 CCR 2650 Recording/reporting <br /> 14 CCR 2635 (b)(2) Overfill prevention system (M2) unauthorized release (M1) <br /> 15 CCR 2631 (a) Primary containment is product 34 HSC 25291 (e) Water in 2° cont analyzed and <br /> tight properly disposed of <br /> 16—CC R 2632 (d) Monitoring&response plan 35 CCR 2640 (e) Single wall component within <br /> 17 CCR 2712 (i) Monitoring&response plan is 1000' of Public Well, no ELD <br /> on site 36 CCR 2635(a)(2)(A)Cathodic protection testing & <br /> 18 CCR 2712 (b) Maintenance &monitoring 60 day inspection log (M2) <br /> records (M1) 37 H&SC 25299(a)(9)Disabling leak detect. Devices <br /> 19 CCR 2636 (f)(4) Annual line tightness test 38 CCR 2715(a) Statement from UST owner <br /> 20 CCR 2630 (d) Annual line leak detector test 39 CCR 2715(c) Monthly inspection by D.O, <br /> (M1) 40 CCR 2715 (f) D.O. trainedemployees <br /> 21 CCR 2630 (d) Annual monitoring certification 41 Violation(s) not listed above <br /> 22 CCR 2661 (f) Repair for tank/piping has had <br /> tightness test{M2 <br /> ;RECEIVED <br /> D INSPECT �— PHONE: oe'# 8 <br /> BY: TITLE <br /> Septic Sy m. Serves ersons/day ❑Receives other than sanitary waste <br /> Other Disposal Units Identified: 0 Dry wells/French Drains <br /> 1AUna15 Unit•1111USnUST 1n5pecl10n8.15.04.DCC <br />
The URL can be used to link to this page
Your browser does not support the video tag.