Laserfiche WebLink
T SAN JOAQUlN COUNTY DATE 'b3 <br /> • 'VIRONMENTAL HEALTH DEPAR*NT PRS <br /> E. Weber Ave., Third Floor, Stockton, CA�'5202PAGE104 E b <br /> (209)468-3420 <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility NameP2G ise OA q' Facility Address 2311 S . S <br /> Facilty ContactJk!QG-&-p1 -4dSAn _Title zlohLm-s Phone# Jr`� <br /> UST#_�' Product.+[m UST# 5 Product UST# (p_Product�'+Et} UST# Product <br /> Overfill Prevention: ❑AudiblelVisual C7'6echanical Monitoring Panel: [r1Cov�._ <br /> Piping System: El Gravity ❑ Pressure 5.513ction Violations: 94inor ❑ Major <br /> Automatic Pump Shut Down Satisfies CCR 2636 (g): ❑Yes ❑ No Dispenser Pan: tomes ❑ No <br /> INSPECTION TYPE: 9Fi6bitine f_NT-bnitoring Certification ❑Complaint ❑install ❑Removal ❑Repair/Upgrade <br /> COMPANYNAME: illi Te-C4-,. TECHNICIAN NAME: Atl &&n— PHONE:532- <br /> VIOLATIONS) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br /> California Code of Regulations (CCR): <br /> I HSC 25284 Permit to operate 20 CCR 2712 (b) Maintenance & monitoring <br /> 2 CCR 2637 Secondary cont testing (6 records <br /> month/36 month) 21 CCR 2636 (f)(4) Annual line tightness test <br /> 3 --CCR 2711(b) & (c) Current State Forms A& B -22 CCR 2630 (d) Annual line leak detector test <br /> 4 HSC 25292,2 Certification of financial 23 CCR 2630 (d) Annual monitoring certification <br /> responsibility and letter from 24 CCR 2643 (d) Daily monitoring of suction <br /> chief financial officer piping that is not continuously <br /> 5 CCR 2630 (d) Continuous monitoring system monitored <br /> for UST system 25 CCR 2636 (a) Conventional suction piping <br /> 6 CCR 2636 (c)(1) All releases in secondary piping shall have continuous <br /> flow to a collection sump monitoring & 20 containment <br /> 7 'HSC 25291 (e) Water in secondary(20)cont 26 CCR 2643 (e) Biennial tightness test of gravit, <br /> 8 HSC 25291 (f) Automatic line leak detector(s) piping that is not continuously <br /> 9 CCR 2636 (f)(1) Continuous monitoring system monitored <br /> for underground piping 27 CCR 2662 Upgrade requirements for UST <br /> 10 CCR 2632 (c)(2) Continuous monitoring system system <br /> for UST 28 CCR 2661 Permit to repair UST system <br /> 11 HSG 25291(a)(2) Secondary containment for 29 HSC 25286 (a) Permit to alter monitoring <br /> UST is tight system <br /> 12 CCR 2636 (f)(1) Continuous monitoring system 30 HSC 25298 (a) Illegal abandonment of UST <br /> for dispenser system system <br /> 13 �CCR 2635 (b)(1) ,Spill container 31 HSC 25298 (b) Permit to temporarily close US- <br /> 14 CCR 2635 (b)(2) Overfill prevention system system <br /> 15 CCR 2631 {a) Primary containment is product- 32 HSC 25298 (c) Permit to close UST system <br /> tight 33 HSC 25291 (e) Water in 20 cont analyzed and <br /> 16 HSC 25292,1 UST system is operated to properly disposed of <br /> prevent unauthorized release 34 CCR 2640 (e) Single wall component within <br /> 17 CCR 2650 Recording/reporting 1000'of Public Well, no EUD <br /> unauthorized release 35 CCR 2635(a)(2)(A) Cathodic protection testing <br /> 18 CCR 2632 (d) Monitoring & response plan 36 H&SC 25299(a)(9)Disabling leak detect. devices <br /> 19 CCR 2712 (i) Monitoring & response plan is 37 Violation(s) not listed above <br /> on site <br /> EHD INSPECTO - I,1iY2 PHONE: 4(P& `(34 <br /> RECEIVED BY: ;-'TITLE: OwnLv` <br /> UNITIIYVSTIINSA(rev 724192) <br />