Laserfiche WebLink
IFIED PROGRAM CONSOLIDATED FW4 / <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION(One form per UST) <br /> TYPE OF ACTION (Check one item only. For an UST permanent closure or removal,complete only this section and Sections I,11,111,IV,and IX below) 430 <br /> El 1.NEW PERMIT [:13.RENEWAL PERMIT [-I5.CHANGE OF INFORMATION <br /> El6.TEMPORARY UST CLOSURE El7.UST PERMANENT CLOSURE ON SITE ® 8.UST REMOVAL kO <br /> DATE UST PERMANENTLY CLOSED:unknown 431e I DATE EXISTING UST DISCOVERED:unknown 430b <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 <br /> San Joaquin County Human Services Agency Building <br /> BUSINESS SrM ADDRESS 103 CITY IN <br /> 145 South Sutter Street Stockton <br /> II.TANK DESCRIPTION <br /> TANK ID# unknown 432 TANK MANUFACTURER 433 TANK CONFIGURATION: THIS TANK IS 434 <br /> Bknown ❑ 1.ASTAND-ALONE TANK <br /> ❑2.ONE INACOMPARTMENTED UNIT. <br /> Com let.one me Por each con mens in the unh. <br /> DATE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT 437 <br /> unknown unknown unknown <br /> III.TANK USE AND CONTENTS <br /> TANK USE ❑ Ia.MOTOR VEHICLE FUELING ❑ Ib.MARINA FUELING ❑ Ic.AVIATION FUELING 439 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Ini.dea Used Oil) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§25281.5(c)) <br /> ❑ 6.OTHER GENERATOR FUEL ® 95.UNKNOWN ❑ 99.OTHER (Specify): 439. <br /> CONTENTS PETROLEUM: ❑ la.REGULAR UNLEADED ❑ le.MIDGRADE UNLEADED ❑ lb.PREMIUM UNLEADED 44o <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (Specify): Unknown 140a <br /> NON-PETROLEUM,❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTHER NON-PETROLEUMS eci : 4406 <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL ® 95.UNKNOWN 443 <br /> PRIMARY CONTAINMENT O 1.STEEL ❑ 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444 <br /> ❑ 7.STEEL+INTERNAL LINING ® 95.UNKNOWN ❑ 99.OTHER (Specify): 444. <br /> SECONDARY CONTAINMENT ❑ 1.STEEL O 3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER U 7.JACKETED 445 <br /> ❑ 90.NONE ® 95.UNKNOWN ❑99.OTHER(Specify): 445. <br /> OVERFILL PREVENTION ❑ 1.AUDIBLE&VISUAL ALARMS ❑ 2.BALL FLOAT ❑ 3.FILL TUBE SHUT-OFF VALVE 452 <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION I ❑ .SINGLE-WALLED ❑2.DOUBLE-WALLED ❑99.OTHER 460 <br /> SYSTEM TYPE ❑ 1 1.PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION 23 CCR§=636(.)(3)] 458 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ &FLEXIBLE ❑ 10.RIGID PLASTIC 464 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 4641, <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464' <br /> PIPINGn URBINE CONTAINMENT SUMP TYPE ❑ 1.SINGLE WALL U 2.DOUBLE WALL ❑ 90.NONE 464d <br /> VI.VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464e <br /> 464e1 <br /> VENT SECONDARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS 10.RIGID PLASTIC ❑ 90.NONE 99.OTHER(Specify) 464f <br /> a64n <br /> VR PRIMARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 4648 <br /> 4641 <br /> VR SECONDARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464h <br /> 464M <br /> VENT PIPING TRANSITION SUMP TYPE ❑ 1.SINGLE WALL [12.DOUBLE WALL O 90.NONE 464i <br /> RISER PRIMARY CONTAINMENT ❑ I.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 4641 <br /> 464'1 <br /> RISER SECONDARY CONTAINMENT ElL STEEL 0 4.FIBERGLASS [110.RIGID PLASTIC [190.NONE 0 99.OTHER(Specify) 4641 <br /> 964kl <br /> FILL COMPONENTS INSTALLED ❑ 1.SPILL BUCKET ❑ 3.STRIKER PLATE/BOTTOM PROTECTOR ❑ 4.CONTAINMENT SUMP 451. <br /> VII.UNDER DISPENSER CONTAINMENT(UDC) <br /> CONSTRUCTION TYPE 1 ❑ I.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90,NONE 169a <br /> CONSTRUCTION MATERIAL 1 ❑ L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTHER(Specify) 4696'' <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ❑ 6.ISOLATION 448. <br /> a. APPLICANT SIGNATURE <br /> CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true,accurate, <br /> and In full compliance with legal requirements. <br /> APPLICANT SIGNATURE DATE 470. <br /> Z (D <br /> APPLICANT NAME(print) 471' APPLICANTTrFLE 7� 472. <br /> Syl r cc <br /> UPCF UST-B-1/2 Rev.(12/2007) <br />