Laserfiche WebLink
�a Feb,,124 03 10: 45a Paul Supple 925 299 8872 p. 3 <br /> dations for N-4828-1-0 (continued) Page 2 of 2 <br /> Initial compliance with VOC emission rate and control efficiency requlrements shall be dcrnonstrated by the results of <br /> the laboratory sample analysis The results shall be submitted to the District within 60 days of the test [Distract Rule <br /> 1081] <br /> 10 The soil remediation system shall be maintained in proper operating condition at all times [District Rule 22011 <br /> 11 Either the VOC control efficiency shall not be less than 95%,or the total VOC emission rate shall not exceed 2 pounds <br /> in any one day [District Rule 2201] <br /> 12 No air contaminant shall be discharged into the atmosphere for a period or periods aggregating more than 3 minutes in <br /> any one hour which is as dark as or darker than Ringelmann 1 or equivalent to 20% opacity [District Rule 41011 <br /> 13 Only natural gas shall be used as auxiliary fuel for the combustion of VOC [Distract Rule 22011 <br /> 14 The minimum operating temperature for the combustion chamber of the thermal oxidizer shall be maintained at or <br /> above 1400 degrees F [District Rule 220 11 <br /> 15 The total VOC emissions from the sail remediation system served by the thermal oxidizer shall not exceed 9 2 pounds <br /> in any one day [District Rule 22011 <br /> lb The total NOx emission rate from the soil remediation system served by the thermal/catalytic oxidizer shall not exceed <br /> 0 1 lb/MMBtu [District Rule 22011 <br /> 17 The total CO emission rate from the soil remediation system served by the thermal/catalytic oxidizer shall not exceed <br /> 0 021 lb/MMBtu [District Rule 2201] <br /> 18 The thermal/catalytic oxidizer shall be equipped with an operational temperature gauge to urdicate the temperature of <br /> the combustion chamber A continuously recording device shall be utilized to indicate the combustion chamber <br /> temperature during operation [District Rule 220 11 <br /> The soil remediation system shall not be operated unless the combustion chamber is at or above mmunum operating <br /> temperature The system shall automatically termuiate operation if the temperature drops below the nvmmum <br /> operating temperature [District Rule 2201] <br /> 20 The total VOC emission rate shall not exceed ten tons in any one calendar year [Distract Rule 22011 <br /> 21 Records of the cumulative running time and the measured influent and effluent VOC concentrations shall be <br /> maintained [District Rule 22011 <br /> 22 All records shall be retained for a minimum of 5 years, and shall be made available for District inspection upon <br /> request [Distract Rule 2-2011 <br />