Laserfiche WebLink
4 <br /> MPE Feasibility Teffells MW-4 and SVE-1 <br /> ARCO Service Station#4932 <br /> 16 East Harding Way <br /> Stockton,California <br /> Applied FLOW SVE Observation Wells <br /> FID Vacuum RATE Induced Vacuum(Inches H2O) <br /> DATE TIME (ppmv) (Hg") (scfm) MW-1 MW-2 MW-3 REMARKS <br /> 2114101 830 — 9 5 65 40 — -- <br /> 2/14/01 930 >10,000 975 7630 002 000 015 <br /> 2114101 1030 >10,000 _1015 8284 -- — High Temperature <br /> 2114101 1115 >10,000 97 6625 -- - <br /> 2/14/01 1130 >10,000 100 8502 002 000 018 High Temperature <br /> 2114/01 1135 >10,000 95 7001 -- -- -- <br /> 2/14/01 1230 >10,000 101 7848 -- -- -- Sampled Influent MW-4 and SVE-1 <br /> 2114/01 230 >10,000 101 7630 003 000 019 <br /> 2/14101 330 >10,000 101 7608 003 000 018 <br /> 2/14/01 430 >10,000 105 8284 003 000 019 <br /> 2114/01 5 30 >101000 100 700 -- -- — System on overnight w/High vacuum liquid nng�_� <br /> 2115101 700 - — -- - - System DOWN upon arrival,faded at 6 00 PM <br /> 2115!01 9 30 -- -- -- -- -- System_off <br /> 2/15/01 1000 >10,000 85 8720 000 000 010 <br /> 2/15101 1100 X10,000 85 8957 000 000 015 <br /> 2115101 1200 >10,000 25 327 000 000 000 Applied vacuum @ MW-4 only,0 5"SPT in knockout <br /> 2115101 1300 >10,000 25 327 000 000 000 <br /> 2115101 1430 >10,000 25 332 0 00 000 000 <br /> 2115/01 1500 >10,000 25 335 - -- -- Sampled MW-4 at 3 00 PM <br /> 2115101 1515 >10,000 65 8499 -- -- -- MW-4 and SVE-1 again <br /> 2/15101 1530 >10,000 85 9919 0 01 -- 017 eein MW-2 pump test <br /> 2115101 1630 >10,000 85 9772 001 016 <br /> 077 43032 030/MPE test table <br />