My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4715
>
2200 - Hazardous Waste Program
>
PR0514152
>
COMPLIANCE INFO 2002 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 11:11:57 AM
Creation date
11/6/2018 8:41:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2015
RECORD_ID
PR0514152
PE
2228
FACILITY_ID
FA0010067
FACILITY_NAME
JIFFY LUBE #2497
STREET_NUMBER
4715
Direction
N
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10437012
CURRENT_STATUS
01
SITE_LOCATION
4715 N WEST LN
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS3\222IAError\IAError\W\WEST\4715\PR0514152\COMPLIANCE INFO 2002 - 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
259
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Dec 281503:45p Jiffy Lube 2497 • 2099521663 p.2 <br /> - 111)SUMMARY OF TANK INSPECTION: IFFIEG EI V E D <br /> A)DATE OF INSPECTION: DEC 2 8 2015 <br /> September 18,2009 <br /> Inspected by:Joe Plecnik Sr. and Rick Vadase ENVIRONMENTAL <br /> �-1�41 TN fiCOn pT��GpT <br /> B) WEATHER CONDITIONS AT DATE OF INSPECTION: <br /> Sunny, 90°F �— <br /> C)PRESENCE OF LEAKS: (At the time of inspection;6 in.of used oil in the tank) <br /> Side Walls . .. . .. . . . . . . . . . . . . . . : None <br /> Manway . . . . .. . . .. . . . . . . . . .. . . :No mamvay present <br /> Nozzles. . . . . .. . . . . . . . . .. . . . . . . :None <br /> Bottom . . . . . . . .. . . . . . .. . . . . .. . : None <br /> Top . . . . .. . . . . .. . . . . . . . . . . . . . . : None <br /> D) INSPECTION OF INDIVIDIJAL TANK OMPONENTS: <br /> 1)INTERIOR SURFACE: <br /> Oil coated but no corrosion. <br /> 2)EXTERIOR SU ACE: <br /> Entire exterior surface is clean without any oil stains. No corrosion or other forms of <br /> degradation on the outside surface. <br /> 3)ANCHOR SYSTEM: <br /> Not provided for seismic loading. <br /> 4)FOUNDATION: <br /> Concrete floor and side walls. Cracking evident throughout the basement where the used <br /> oil tank is located. However,the cracks are generally thin and filled with oily deposits. <br /> Hence,these cracks are essentially sealed in future oil spills. <br /> 5)CONTAINMENT: <br /> Underground concrete cellar also used for storage supplies. The used oil tank is located <br /> in one corner of the cellar up against two walls. The tank is approximately 1 in.to 2 in. <br /> from these two walls. <br /> 6)NOZZLES AND FITTINGS: <br /> Three 2 in.diameter steel fittings used for venting, filling,and emptying the tatik. One <br /> 4 in. diameter fitting used for venting. Two 6 in.diameter vents without known usage. <br /> 7) MANWAYS: <br /> None <br />