Laserfiche WebLink
0 <br /> m <br /> 0 <br /> N <br /> 00 <br /> Table 7 — Assessment of Used Oil Tank System AXOM 01 <br /> 0 <br /> Jiffy Lube Store #2497, Stockton, CA W <br /> v, <br /> Citation Requirement Assessment Findings <br /> Section 66266.192. (b)The owner or operator of a new tank system shall ensure that proper The tank has been in operation for ten years or longer.No <br /> Design and handling procedures are adhered to In order to prevent damage to the records of an Inspection at the time of installation are available. <br /> Installation of Now system during installation. Prior to covering, enclosing,or placing a new r <br /> Tank Systems and tank system or component in use, an independent, qualified installation On April 9, 2014, Mr. Chris Womack, Installation Inspector, m <br /> Components. inspector or an independent,qualified, professional engineer, registered AECOM conducted a visual inspection of the tank in the current <br /> (continued) In California, either of whom is trained and experienced in the proper operating configuration. No evidence of structural damage. V <br /> installation of tank systems, shall inspect the system or component for breaks, cracks or corrosion, and no evidence of inadequate <br /> the presence of any of the following items: construction or installation was observed. • <br /> (1)weld breaks; The tank was tightness tested on April 9,2014 by Mr.Chris <br /> Womack. The primary tank and interstitial space both passed <br /> (2)punctures; lightness testing. <br /> (3)scrapes of protective coatings; On August 22, 2014, the tank system was retrofitted to meet <br /> applicable code requirements, and then re-inspected. No <br /> (4)cracks; evidence of structural damage, breaks, cracks or significant <br /> (5)corrosion; corrosion and no evidence of inadequate construction or <br /> installation were observed. <br /> (6)other structural damage or inadequate construction or installation.All <br /> discrepancies shall be remedied before the tank system is covered, <br /> enclosed, or placed in use. <br /> (c)New tank systems or components and piping that are placed Not applicable.Although the tank system Is located below grade, <br /> underground and that are backfilled shall the tank and associated components are in a basement and are <br /> ...[remaining omitted–subsectionnot applicable) not backfilled. <br /> cc <br /> (d)All new tanks and ancillary equipment shall be tested for tightness The tank and system was tightness tested by AECOM on April 9, •N <br /> prior to being covered, enclosed or placed in use. If a tank system is 2014 in accordance with NFPA 30 (2008 Ed.), Section 21.5.2 o <br /> found not to be tight,all repairs necessary to remedy the leak(s) in the and it passed(Attachment 2). w <br /> system shall be performed prior to the tank system being covered, <br /> enclosed, or placed in use. <br /> — -- .. <br /> ;a � C7 <br /> � IT <br /> u lz- op <br /> -3- +117 o <br /> J UI <br /> 1� Mp�-, <br /> 11 1 <br />