My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002 - 2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
18754
>
2300 - Underground Storage Tank Program
>
PR0507164
>
COMPLIANCE INFO_2002 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:35 AM
Creation date
11/6/2018 9:27:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2008
RECORD_ID
PR0507164
PE
2361
FACILITY_ID
FA0007722
FACILITY_NAME
ORLANDOS
STREET_NUMBER
18754
Direction
E
STREET_NAME
STATE ROUTE 26
City
LINDEN
Zip
95236
APN
10517048
CURRENT_STATUS
01
SITE_LOCATION
18754 E HWY 26
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\HWY 26\18754\PR0507164\COMPLIANCE INFO 2002 - 2008 .PDF
QuestysFileName
COMPLIANCE INFO 2002 - 2008
QuestysRecordDate
1/17/2017 5:26:41 PM
QuestysRecordID
3312375
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicio <br />Software Version Installed: <br />Coy+plete the followine checklist: <br />0 <br />s <br />❑ No* <br />Is the audible alarm operational? <br />s <br />❑ No* <br />Is the visual alarm o emtional? <br />❑ No* <br />Were all sensors visually inspected, functionally tested. and confirmed operational? <br />es <br />Cl No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />will <br />not interfere with their proper o ration? <br />❑ Yes <br />❑ <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />N/A <br />operational? <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />monitoring system detects a leak, fails to operafpt or is electrically disconn ? If yes: which sensors initiate <br />shut -down? (Check . <br />positive all that apply) sumparench Sensors; tspenser�Con � nt Sensors. <br />Did ou confirm sitive shut -down due to leaks and sensor failure/disconnection? M*Tes; C2 No. <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />jYesN'* <br />fill oint(s) and o tin roer1 ? If so, at what rcent of tank ca aci does the alarm triger? <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all re lacement arts in Section E, below. <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) ❑Product; <br />❑ Water. If es, describe causes in Section E, below. <br />Was monimrin s stem set -u reviewed to ensure r r settin s? Attach set u re rts, if a licable <br />Is all monitmin i ment o ational r manufacturer's ' mcations? <br />in Section E; oeiow, descrine now and when these deficiencies were or will be corrected. <br />E. Comments: <br />Page 2 of 3 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.